Your browser doesn't support javascript.
loading
Mechanical hemolysis in a hemodialysis patient with carotid-jugular arteriovenous fistula.
Kuo, K L; Chou, Y H; Tarng, D C.
Afiliação
  • Kuo KL; Division of Nephrology, Department of Medicine, Taipei Veterans General Hospital, and Faculty of Medicine, National Yang-Ming University School of Medicine, Taipei, Taiwan.
Clin Nephrol ; 61(1): 74-7, 2004 Jan.
Article em En | MEDLINE | ID: mdl-14964462
ABSTRACT
Renal anemia is mainly caused by inadequate synthesis of erythropoietin from diseased kidneys. At the present time, recombinant human erythropoietin (rHuEPO) is used to correct anemia successfully in most patients with end-stage renal diseases. Nevertheless, poor response to rHuEPO still exists in some hemodialysis patients and its mechanism in some cases remains obscure. Herein, we describe a rare case of rHuEPO hyporesponsiveness due to mechanical hemolysis induced by a traumatic carotid-jugular arteriovenous fistula (AVF) in the presence of subclinical aluminum intoxication. Following surgical resection of the traumatic AVF and 8 months of desferrioxamine treatment, the responsiveness to rHuEPO was restored and the rHuEPO dose requirements reduced.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças das Artérias Carótidas / Fístula Arteriovenosa / Diálise Renal / Hemólise / Veias Jugulares Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças das Artérias Carótidas / Fístula Arteriovenosa / Diálise Renal / Hemólise / Veias Jugulares Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2004 Tipo de documento: Article