Your browser doesn't support javascript.
loading
Uniform vascular contrast enhancement and reduced contrast medium volume achieved by using exponentially decelerated contrast material injection method.
Bae, Kyongtae T; Tran, Huy Q; Heiken, Jay P.
Afiliação
  • Bae KT; Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, Box 8131, St Louis, MO 63110, USA. baet@mir.wustl.edu
Radiology ; 231(3): 732-6, 2004 Jun.
Article em En | MEDLINE | ID: mdl-15163812
ABSTRACT

PURPOSE:

To investigate in computed tomographic (CT) angiography whether an exponentially decelerated contrast medium injection, as compared with a standard constant-rate injection, can facilitate uniform vascular contrast enhancement with a reduced contrast material volume. MATERIALS AND

METHODS:

CT angiography of the abdominal aorta was performed in 46 subjects by using an exponentially decelerated injection

method:

134 mL of contrast medium was injected for 40 seconds, starting at 4.0 mL/sec and decreasing exponentially to 2.7 mL/sec by the end of the injection. Twenty-one of these subjects also underwent CT angiography with a constant-rate injection 160 mL of contrast medium was injected for 40 seconds at a constant rate of 4 mL/sec. Time-enhancement curves and the magnitude of peak vascular enhancement were measured. Enhancement uniformity was evaluated by using three indexes (a) duration of contrast enhancement achieved within 80% of the peak (80% DCE), (b) SD of the normalized contrast enhancement (SDNCE) measured from the beginning of spiral CT scanning to the time when the enhancement decreased to a level lower than the beginning level, and (c) slope of the enhancement curve calculated by using linear regression analysis.

RESULTS:

Exponentially decelerated injection resulted in more uniform enhancement. Mean values generated by using exponentially decelerated versus constant-rate injection in 21 paired comparisons were, respectively, 30.8 seconds +/- 5.0 versus 22.6 seconds +/- 7.6 for 80% DCE, 0.052 +/- 0.017 versus 0.086 +/- 0.031 for SDNCE, and 0.47 HU/sec +/- 0.70 versus 2.27 HU/sec +/- 0.87 for slope (P <.001 for all indexes). Compared with the peak enhancement resulting from the constant-rate injection, that resulting from the exponentially decelerated injection was reduced by a mean of 17.2% +/- 10.0.

CONCLUSION:

Uniform vascular contrast enhancement and reduced contrast medium volume, which are desirable in CT angiography, can be achieved with exponentially decelerated injection.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Tri-Iodobenzoicos / Angiografia / Tomografia Computadorizada por Raios X / Meios de Contraste Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácidos Tri-Iodobenzoicos / Angiografia / Tomografia Computadorizada por Raios X / Meios de Contraste Limite: Aged / Female / Humans / Male Idioma: En Ano de publicação: 2004 Tipo de documento: Article