Your browser doesn't support javascript.
loading
Comparison of a Duraflo II-coated cardiopulmonary bypass circuit and a trillium-coated oxygenator during open-heart surgery.
Hoel, Tom N; Videm, Vibeke; Baksaas, Svein T; Mollnes, Tom E; Brosstad, Frank; Svennevig, Jan L.
Afiliação
  • Hoel TN; Department of Thoracic and Cardiovascular Surgery, Rikshospitalet University Hospital, Oslo, Norway. tom.nilsen.hoel@rikshospitalet.no
Perfusion ; 19(3): 177-84, 2004 May.
Article em En | MEDLINE | ID: mdl-15298426
ABSTRACT

BACKGROUND:

Cardiopulmonary bypass (CPB) evokes a systemic inflammatory response. In attempting to improve the biocompatibility of the equipment, various methods to coat the inner surfaces of the CPB systems have been developed. The present study compares a Trillium Biopassive surface-coated Affinity oxygenator with a Duraflo II totally heparin-coated CPB system.

METHODS:

Low-risk patients admitted for primary coronary artery bypass grafting or aortic valve replacement were randomized to operation using the Trillium- or the Duraflo II-coated setups. Heparin concentration, complement activation (C3bc activation products and terminal complement complex (TCC)), platelet activation (platelet numbers and beta-thromboglobulin (BTG)), leukocyte activation (leukocyte numbers and myeloperoxidase (MPO)), coagulation (thrombin/antithrombin complexes (TAT)) and fibrinolytic activity (plasmin/alpha2-antiplasmin complexes (PAP)) were measured during CPB and two hours postoperatively.

RESULTS:

Platelet counts decreased during CPB, without significant intergroup differences. The median BTG concentration increased moderately in both groups and were slightly higher in the Trillium group during CPB (p < 0.05), but not postoperatively. Complement activation products (C3bc and TCC), leukocyte counts, MPO, TAT and PAP activity showed no differences between the two groups.

CONCLUSIONS:

There were small differences in the inflammatory response between the two extracorporeal circulation devices compared in this study.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigenadores / Ponte Cardiopulmonar / Materiais Revestidos Biocompatíveis / Trillium / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Clinical_trials Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2004 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigenadores / Ponte Cardiopulmonar / Materiais Revestidos Biocompatíveis / Trillium / Procedimentos Cirúrgicos Cardíacos Tipo de estudo: Clinical_trials Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2004 Tipo de documento: Article