Your browser doesn't support javascript.
loading
Detection of liver metastases from endocrine tumors: a prospective comparison of somatostatin receptor scintigraphy, computed tomography, and magnetic resonance imaging.
Dromain, Clarisse; de Baere, Thierry; Lumbroso, Jean; Caillet, Hubert; Laplanche, Agnès; Boige, Valerie; Ducreux, Michel; Duvillard, Pierre; Elias, Dominique; Schlumberger, Martin; Sigal, Robert; Baudin, Eric.
Afiliação
  • Dromain C; Department of Radiology, Institut Gustave-Roussy, 39, rue Camille Desmoulins, 94805 Villejuif Cedex, France. dromain@igr.fr
J Clin Oncol ; 23(1): 70-8, 2005 Jan 01.
Article em En | MEDLINE | ID: mdl-15625361
ABSTRACT

PURPOSE:

To compare the respective sensitivity of somatostatin receptor scintigraphy (SRS), computed tomography (CT), and magnetic resonance imaging (MRI) in the detection of liver metastases from well-differentiated gastroenteropancreatic endocrine tumor (WDGEP ET) patients. To define predictive factors for "high-sensitivity SRS." PATIENTS AND

METHODS:

Sixty-four patients with WDGEP ET underwent SRS with abdominal single-photon emission computed tomography (SPECT), spiral CT, and 1.5-T MRI within a 15-day interval, the order of which was randomized. Two readers analyzed images of each modality, blindly and independently.

RESULTS:

Hepatic metastases were present in 40 of the 64 patients and confirmed by pathology after liver biopsy or surgery in 32 and eight patients, respectively. SRS, CT, and MRI detected a total of 204, 325, and 394 metastases, respectively. The number of detected metastases was significantly higher with MRI than with CT (P = .02) and SRS (P < 10(-4)) and higher with CT than with SRS (P < 10(-4)). SRS was negative in seven patients with a positive CT and/or MRI. More lesions were detected in 10 patients by SPECT compared with static views. The median metastasis size was significantly correlated (P = .04) with the sensitivity of SRS.

CONCLUSION:

MRI seems to have an edge over CT and SRS for the detection of liver metastases from endocrine tumors. We recommend the systematic performance of liver MRI at WDGEP ET initial staging and before major therapeutic events. The low performance of SRS was mainly explained by the impact of the metastasis size on the detection capacity of SRS.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Tomografia Computadorizada de Emissão de Fóton Único / Neoplasias das Glândulas Endócrinas / Neoplasias Hepáticas Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X / Tomografia Computadorizada de Emissão de Fóton Único / Neoplasias das Glândulas Endócrinas / Neoplasias Hepáticas Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article