Your browser doesn't support javascript.
loading
Cheyne-Stokes respiration in stroke: relationship to hypocapnia and occult cardiac dysfunction.
Nopmaneejumruslers, Cherdchai; Kaneko, Yasuyuki; Hajek, Vlasta; Zivanovic, Vera; Bradley, T Douglas.
Afiliação
  • Nopmaneejumruslers C; Sleep Research Laboratory of the Toronto Rehabilitation Institute, Centre for Sleep Medicine and Circadian Biology of the University of Toronto, Toronto, Ontario, Canada.
Am J Respir Crit Care Med ; 171(9): 1048-52, 2005 May 01.
Article em En | MEDLINE | ID: mdl-15665317
ABSTRACT

BACKGROUND:

Central sleep apnea (CSA) and Cheyne-Stokes respiration have been reported in association with stroke, but their pathophysiologic correlates have not been well described.

OBJECTIVE:

To test the hypotheses that (1) CSA in patients with stroke is associated with nocturnal hypocapnia and (2) in those stroke patients with CSA and with left ventricular (LV) systolic dysfunction, periodic breathing (PB) will have a Cheyne-Stokes respiration pattern in which cycle duration is greater than in those without LV systolic dysfunction.

METHODS:

We prospectively performed polysomnography and echocardiography in 93 patients with stroke. CSA was defined as central apneas and hypopneas occurring at a rate of 10 or more per hour of sleep. In patients with CSA, we compared PB cycle duration between those with normal and impaired LV systolic function (LV ejection fraction [LVEF] > 40% and < or = 40%, respectively).

RESULTS:

CSA was found in 19% of subjects who had lower nocturnal transcutaneous PCO2 (39.3 +/- 0.9 vs. 42.8 +/- 0.8 mmHg, p = 0.015) and a higher prevalence of LVEF of 40% or less (22 vs. 5%, p = 0.043) than stroke patients without CSA. There was no significant difference in stroke location or type between the two groups. In patients with CSA, those with LVEF of 40% or less had a longer PB cycle than those with an LVEF of more than 40% (66.6 +/- 5.6 vs. 46.6 +/- 2.9 seconds, p = 0.006), but had no symptoms of heart failure.

CONCLUSION:

In patients with stroke, CSA is associated with hypocapnia and occult LV systolic dysfunction but is not related to the location or type of stroke. The presence of LV systolic dysfunction is associated with a Cheyne-Stokes pattern of hyperpnea.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração de Cheyne-Stokes / Hipocapnia / Apneia do Sono Tipo Central / Acidente Vascular Cerebral Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Respiração de Cheyne-Stokes / Hipocapnia / Apneia do Sono Tipo Central / Acidente Vascular Cerebral Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article