Your browser doesn't support javascript.
loading
Image quality of volume rendering of the bronchial tree: Kymogram-gated versus retrospectively ECG-gated and non-gated multi-row detector CT.
Boehm, Thomas; Alkadhi, Hatem; Sennst, Dirk-Alexander; Schertler, Thomas; Kachelriess, M; Kalender, Willi; Marincek, Borut; Wildermuth, Simon.
Afiliação
  • Boehm T; Department of Radiology, Spitäler Chur AG, Loestrasse 170, CH-7000 Chur, Switzerland. Thomas_Boehm@gmz.net
Acad Radiol ; 12(2): 173-81, 2005 Feb.
Article em En | MEDLINE | ID: mdl-15721594
ABSTRACT
RATIONALE AND

OBJECTIVE:

To compare the image quality of three different heart-cycle-synchronized computed tomography (CT) reconstruction algorithms for volume-rendered (VR) 3D visualization of the bronchial tree. MATERIALS AND

METHODS:

Kymogram-gated, retrospectively ECG-gated, and non-ECG-gated reconstructions of the bronchial tree were performed from 4-detector-row CT data in 10 subjects. The raw data were reconstructed in 10 phases of the cardiac cycle using ECG-gated and kymogram-gated technique, respectively. For both reconstructions, the optimal artifact-free diastolic phase was determined. VR reconstructions of the bronchial tree were generated from these two data sets and from the non-gated data. Stairstep artifacts of the main bronchi, artifacts in the lung parenchyma, and the extent of bronchial tree visualization were rated by two blinded, independent readers.

RESULTS:

Kymogram-gated reconstruction showed stairstep artifacts in the main bronchi to the same extent as non-gated reconstruction, but less compared to ECG-gated reconstruction (P < .001). Artifacts in the lung parenchyma were similar with kymogram-gated and non-gated reconstruction, but less compared to ECG-gated reconstruction (P < 0.01). Kymogram-gated reconstruction showed no differences in visualization of segmental and subsegmental bronchi compared to ECG-gated reconstruction, but was inferior to the non-gated reconstruction (P < 0.05).

CONCLUSION:

Kymogram-gated reconstruction of CT data results in fewer artifacts when compared to the ECG-gated algorithm. Best visualization of the bronchial tree at a low artifact level is obtained with non-gated CT data. It remains therefore the method of choice for VR 3D data post-processing of the bronchial tree.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Broncografia / Intensificação de Imagem Radiográfica / Tomografia Computadorizada por Raios X / Eletrocardiografia Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Broncografia / Intensificação de Imagem Radiográfica / Tomografia Computadorizada por Raios X / Eletrocardiografia Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2005 Tipo de documento: Article