Measurement of temperature-dependent specific heat of biological tissues.
Physiol Meas
; 26(1): 59-67, 2005 Feb.
Article
em En
| MEDLINE
| ID: mdl-15742879
We measured specific heat directly by heating a sample uniformly between two electrodes by an electric generator. We minimized heat loss by styrofoam insulation. We measured temperature from multiple thermocouples at temperatures from 25 degrees C to 80 degrees C while heating the sample, and corrected for heat loss. We confirm method accuracy with a 2.5% agar-0.4% saline physical model and obtain specific heat of 4121+/-89 J (kg K)(-1), with an average error of 3.1%.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Termômetros
/
Temperatura Alta
Tipo de estudo:
Evaluation_studies
/
Prognostic_studies
Limite:
Animals
/
Humans
Idioma:
En
Ano de publicação:
2005
Tipo de documento:
Article