Stability of human immunodeficiency virus type 1 proviral DNA in whole-blood samples.
J Clin Microbiol
; 43(8): 4249-50, 2005 Aug.
Article
em En
| MEDLINE
| ID: mdl-16081991
ABSTRACT
The Roche Amplicor HIV-1 Test requires that whole blood be processed within four days of collection. However, this requirement may be too limiting for use in international settings. Thus, we demonstrate that blood may be processed up to 10 days after collection if maintained under ambient conditions (2 to 25 degrees C).
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Preservação de Sangue
/
DNA Viral
/
HIV-1
/
Provírus
Limite:
Humans
Idioma:
En
Ano de publicação:
2005
Tipo de documento:
Article