ABSTRACT

PURPOSE:

To compare a commercial CT colonography software ("Colonography", Siemens, Forchheim) with a non-commercial post-processing system ("Colotux", Department of Informatics). MATERIAL AND

METHODS:

Identical data sets of 10 patients, who underwent an ultra-low-dose multi-detector CT colonography (ULD-MDCTC) (4x1 mm collimation, 8 mm pitch, 120 kVp, 10 mAs) were analyzed retrospectively. Assessment was performed using both software solutions by two resident radiologists, who did not have any experience with any colonography software tool before and who did not know the clinical symptoms of the patients or the results of the conventional colonoscopy. Both systems were analyzed using several subjective quality criteria including workflow, handling, image quality, endoluminal navigation and analysis of lesions with grading on a 5-point-scale. Results concerning polyps were compared between the two systems as well as with conventional colonoscopy.

RESULTS:

Both colonography systems detected the same number of polyps. Although both showed some advantages for single criteria, no relevant difference was noted in general for subjective assessment. The time for calculation of three dimensional interactive volumes was three times longer for "Colotux" compared to "Colonography." Linux-based "Colotux" showed a trend towards better subjective image quality and easier measurement of polyp size. An intuitive desktop and "Syngo"-workflow integration were advantages of "Colonography."

CONCLUSION:

The analysis of CT colonographies (4-detector-row-CT-scanner, ultra low dose technique, supine position) can adequately be achieved by both software solutions. There was no significant subjective or objective difference of quality between a "stand-alone" individual system and a commercial workflow-integrated solution. A relevant factor for decision between the two systems may be the difference in time needed for the 3D volume calculation, especially in institutes with a high frequency of examinations.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Software / Colonografia Tomográfica Computadorizada Tipo de estudo: Evaluation_studies / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: De Ano de publicação: 2005 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Software / Colonografia Tomográfica Computadorizada Tipo de estudo: Evaluation_studies / Observational_studies / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: De Ano de publicação: 2005 Tipo de documento: Article