[Removal of arsenic (II) by ferrate oxidation-coagulation from drinking water].
Huan Jing Ke Xue
; 27(2): 281-4, 2006 Feb.
Article
em Zh
| MEDLINE
| ID: mdl-16686189
Ferrate is multi-function agent in water treatment and shows great oxidizing ability and excellent purifying effect. This experiment evaluated the performance of ferrate for arsenic removal. Experimental results show that the best rate of ferrate and arsenic (III) is 15:1, the efficiency of As removal can be achieved 98%, and the residual concentration of As3 + is < 0.05 mg/L. The optimum pH is 5.5 to approximately 7.5. The oxidative and coagulation time is 10 min and 30 min respectively. The salinity and hardness did not interfere with removal arsenic. This method is easy, very effective comparing with ferric method and KMnO4-Ferric method.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Arsênio
/
Poluentes Químicos da Água
/
Abastecimento de Água
/
Purificação da Água
/
Ferro
Idioma:
Zh
Ano de publicação:
2006
Tipo de documento:
Article