Your browser doesn't support javascript.
loading
Sirolimus-eluting versus uncoated stents in acute myocardial infarction.
Spaulding, Christian; Henry, Patrick; Teiger, Emmanuel; Beatt, Kevin; Bramucci, Ezio; Carrié, Didier; Slama, Michel S; Merkely, Bela; Erglis, Andrejs; Margheri, Massimo; Varenne, Olivier; Cebrian, Ana; Stoll, Hans-Peter; Snead, David B; Bode, Christoph.
Afiliação
  • Spaulding C; Assistance Publique-Hôpitaux de Paris (AP-HP) Cochin Hospital, Paris 5 Medical School Rene Descartes University and INSERM U780, Paris, France. christian.spaulding@cch.ap-hop-paris.fr
N Engl J Med ; 355(11): 1093-104, 2006 Sep 14.
Article em En | MEDLINE | ID: mdl-16971716
ABSTRACT

BACKGROUND:

Sirolimus-eluting stents reduce rates of restenosis and reintervention, as compared with uncoated stents. Data are limited regarding the safety and efficacy of such stents in primary percutaneous coronary intervention (PCI) for acute myocardial infarction with ST-segment elevation.

METHODS:

We performed a single-blind, multicenter, prospectively randomized trial to compare sirolimus-eluting stents with uncoated stents in primary PCI for acute myocardial infarction with ST-segment elevation. The trial included 712 patients at 48 medical centers. The primary end point was target-vessel failure at 1 year after the procedure, defined as target-vessel-related death, recurrent myocardial infarction, or target-vessel revascularization. A follow-up angiographic substudy was performed at 8 months among 174 patients from selected centers.

RESULTS:

The rate of the primary end point was significantly lower in the sirolimus-stent group than in the uncoated-stent group (7.3% vs. 14.3%, P=0.004). This reduction was driven by a decrease in the rate of target-vessel revascularization (5.6% and 13.4%, respectively; P<0.001). There was no significant difference between the two groups in the rate of death (2.3% and 2.2%, respectively; P=1.00), reinfarction (1.1% and 1.4%, respectively; P=1.00), or stent thrombosis (3.4% and 3.6%, respectively; P=1.00). The degree of neointimal proliferation, as assessed by the mean (+/-SD) in-stent late luminal loss, was significantly lower in the sirolimus-stent group (0.14+/-0.49 mm, vs. 0.83+/-0.52 mm in the uncoated stent group; P<0.001).

CONCLUSIONS:

Among selected patients with acute myocardial infarction, the use of sirolimus-eluting stents significantly reduced the rate of target-vessel revascularization at 1 year. (ClinicalTrials.gov number, NCT00232830 [ClinicalTrials.gov].).
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Sirolimo / Imunossupressores / Infarto do Miocárdio Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2006 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Stents / Sirolimo / Imunossupressores / Infarto do Miocárdio Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2006 Tipo de documento: Article