Measurement of a low-absorption sample of OH-reduced fused silica.
Appl Opt
; 45(28): 7269-72, 2006 Oct 01.
Article
em En
| MEDLINE
| ID: mdl-16983413
Low-absorption optics made of OH-reduced fused silica are a key technology for future gravitational wave detectors such as the Advanced LIGO. We developed a sensitive method to measure the absorption inside the beam splitter of the GEO 600, taking advantage of the effect of thermal lensing. Using this method, we derived a bulk absorption of less than 0.25 ppm/cm for a piece of Suprasil 311 SV at a wavelength of 1064 nm. To the best of our knowledge, this is the lowest value of light absorption inside fused silica reported so far in the literature.
Buscar no Google
Coleções:
01-internacional
Base de dados:
MEDLINE
Idioma:
En
Ano de publicação:
2006
Tipo de documento:
Article