Measurement of a low-absorption sample of OH-reduced fused silica.
Hild, Stefan; Lück, Harald; Winkler, Walter; Strain, Ken; Grote, Hartmut; Smith, Joshua; Malec, Michaela; Hewitson, Martin; Willke, Benno; Hough, James; Danzmann, Karsten.
Afiliação
  • Hild S; Max-Plack-Institut fur Gravitationsphysik (Albert-Einstein-Institut) and Universität Hannover, Germany. stefan.hild@aei.mpg.de
Appl Opt ; 45(28): 7269-72, 2006 Oct 01.
Article em En | MEDLINE | ID: mdl-16983413
Low-absorption optics made of OH-reduced fused silica are a key technology for future gravitational wave detectors such as the Advanced LIGO. We developed a sensitive method to measure the absorption inside the beam splitter of the GEO 600, taking advantage of the effect of thermal lensing. Using this method, we derived a bulk absorption of less than 0.25 ppm/cm for a piece of Suprasil 311 SV at a wavelength of 1064 nm. To the best of our knowledge, this is the lowest value of light absorption inside fused silica reported so far in the literature.