Your browser doesn't support javascript.
loading
Bolus characteristics based on Magnetic Resonance Angiography.
Cai, Zhijun; Stolpen, Alan; Sharafuddin, Melhem J; McCabe, Robert; Bai, Henri; Potts, Tom; Vannier, Michael; Li, Debiao; Bi, Xiaoming; Bennett, James; Golzarian, Jafar; Sun, Shiliang; Wang, Ge; Bai, Er-Wei.
Afiliação
  • Cai Z; Department of Electrical and Computer Engineering, University of Iowa, Iowa City, IA, USA. zhijun-cai@uiowa.edu
Biomed Eng Online ; 5: 53, 2006 Oct 17.
Article em En | MEDLINE | ID: mdl-17044929
ABSTRACT

BACKGROUND:

A detailed contrast bolus propagation model is essential for optimizing bolus-chasing Computed Tomography Angiography (CTA). Bolus characteristics were studied using bolus-timing datasets from Magnetic Resonance Angiography (MRA) for adaptive controller design and validation.

METHODS:

MRA bolus-timing datasets of the aorta in thirty patients were analyzed by a program developed with MATLAB. Bolus characteristics, such as peak position, dispersion and bolus velocity, were studied. The bolus profile was fit to a convolution function, which would serve as a mathematical model of bolus propagation in future controller design.

RESULTS:

The maximum speed of the bolus in the aorta ranged from 5-13 cm/s and the dwell time ranged from 7-13 seconds. Bolus characteristics were well described by the proposed propagation model, which included the exact functional relationships between the parameters and aortic location.

CONCLUSION:

The convolution function describes bolus dynamics reasonably well and could be used to implement the adaptive controller design.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Meios de Contraste / Doenças das Valvas Cardíacas / Modelos Cardiovasculares Tipo de estudo: Evaluation_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2006 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Interpretação de Imagem Assistida por Computador / Angiografia por Ressonância Magnética / Meios de Contraste / Doenças das Valvas Cardíacas / Modelos Cardiovasculares Tipo de estudo: Evaluation_studies / Observational_studies / Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2006 Tipo de documento: Article