Your browser doesn't support javascript.
loading
Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode.
Safavi, Afsaneh; Maleki, Norouz; Moradlou, Omran; Tajabadi, Fariba.
Afiliação
  • Safavi A; Department of Chemistry, Faculty of Sciences, Shiraz University, Shiraz 71454, Iran. safavi@chem.susc.ac.ir
Anal Biochem ; 359(2): 224-9, 2006 Dec 15.
Article em En | MEDLINE | ID: mdl-17069745
ABSTRACT
A recently constructed carbon composite electrode using room temperature ionic liquid as pasting binder was employed as a novel electrode for sensitive, simultaneous determination of dopamine (DA), ascorbic acid (AA), and uric acid (UA). The apparent reversibility and kinetics of the electrochemical reaction for DA, AA, and UA found were improved significantly compared to those obtained using a conventional carbon paste electrode. The results show that carbon ionic liquid electrode (CILE) reduces the overpotential of DA, AA, and UA oxidation, without showing any fouling effect due to the deposition of their oxidized products. In the case of DA, the oxidation and reduction peak potentials appear at 210 and 135mV (vs Ag/AgCl, KCl, 3.0M), respectively, and the CILE shows a significantly better reversibility for dopamine. The oxidation peak due to the oxidation of AA occurs at about 60mV. For UA, a sharp oxidation peak at 340mV and a small reduction peak at 250mV are obtained at CILE. Differential pulse voltammetry was used for the simultaneous determination of ternary mixtures of DA, AA, and UA. Relative standard deviation for DA, AA, and UA determinations were less than 3.0% and DA, AA, and UA can be determined in the ranges of 2.0x10(-6)-1.5x10(-3), 5.0x10(-5)-7.4x10(-3), and 2.0x10(-6)-2.2x10(-4)M, respectively. The method was applied to the determination of DA, AA, and UA in human blood serum and urine samples.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Ascórbico / Ácido Úrico / Carbono / Técnicas Biossensoriais / Dopamina / Líquidos Iônicos / Microeletrodos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2006 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ácido Ascórbico / Ácido Úrico / Carbono / Técnicas Biossensoriais / Dopamina / Líquidos Iônicos / Microeletrodos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2006 Tipo de documento: Article