Electronic monitoring of adherence as a tool to improve blood pressure control. A randomized controlled trial.
Wetzels, Gwenn E C; Nelemans, Patricia J; Schouten, Jan S A G; Dirksen, Carmen D; van der Weijden, Trudy; Stoffers, Henri E J H; Janknegt, Rob; de Leeuw, Peter W; Prins, Martin H.
Afiliação
  • Wetzels GE; Department of Epidemiology, Care and Public Health Research Institute (CAPHRI), University of Maastricht, Maastricht, The Netherlands. gwenn.wetzels@epid.unimaas.nl
Am J Hypertens ; 20(2): 119-25, 2007 Feb.
Article em En | MEDLINE | ID: mdl-17261454
ABSTRACT

BACKGROUND:

Poor adherence to antihypertensive drug regimens is believed to be a major contributor to treatment failure. Electronic monitoring of adherence may improve adherence and allow differentiation between those who are nonadherent and those who are pharmacologically nonresponsive. This study was designed to evaluate the effectiveness of electronic monitoring of adherence in lowering blood pressure (BP) in comparison with usual care.

METHODS:

A total of 258 patients with high BP despite use of antihypertensive medication were randomly assigned to either continuation of usual care (with adjustment in antihypertensive medication if necessary) or to the introduction of electronic monitoring. Adherence to antihypertensive medication was monitored for 2 months without medication changes. The primary outcome measure was the proportion of patients who reached target BP levels after a 5-month follow-up period.

RESULTS:

At 5 months, 50.6% of the patients in the usual care group reached adequate BP, v 53.7% in the electronic monitoring group (P = .73). The percentages of patients with drug additions or increases in dosage were higher in the usual care group compared with those in whom adherence was monitored (P < .01).

CONCLUSION:

These data show that electronic monitoring in comparison to usual care results in similar BP control but leads to fewer drug changes and less drug use. This result is likely to be achieved by improving adherence. Hence a strategy that includes electronic monitoring has the potential to prevent unnecessary treatment escalation in patients with poor adherence.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cooperação do Paciente / Monitorização Ambulatorial / Monitorização Ambulatorial da Pressão Arterial / Eletrônica Médica / Hipertensão Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cooperação do Paciente / Monitorização Ambulatorial / Monitorização Ambulatorial da Pressão Arterial / Eletrônica Médica / Hipertensão Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article