Sub-foveal choroidal blood flow by LDF: measurement and application to the physiology and pathology of the choroidal circulation.
Riva, C E.
Afiliação
  • Riva CE; Institut de Recherche en Ophtalmologie, Sion, Switzerland. charles.riva@netplus.ch
Bull Soc Belge Ophtalmol ; (302): 185-94, 2006.
Article em En | MEDLINE | ID: mdl-17265798
ABSTRACT
Laser Doppler flowmetry allows the measurement of relative choroidal blood flow in the sub-foveal region of the fundus (ChBF). This technique has been applied to the investigation of the regulation of ChBF in response to a variety of physiological stimuli (breathing different gas mixtures of O2 and CO2, varying the systemic and ocular blood perfusion pressures, light-dark transition and zero gravity) in normal subjects. Measurements in pathological conditions, such as diabetes, age-related macular degeneration and glaucoma indicate alterations of the response of ChBF to increased systemic blood pressure. The data provide a better understanding of the regulation of the choroidal circulation in the normal and diseased eye.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Corioide / Fluxometria por Laser-Doppler Limite: Animals / Humans Idioma: En Ano de publicação: 2006 Tipo de documento: Article