The impact of positron emission tomography/computed tomography in edge delineation of gross tumor volume for head and neck cancers.
Ashamalla, Hani; Guirgius, Adel; Bieniek, Ewa; Rafla, Sameer; Evola, Alex; Goswami, Ganesh; Oldroyd, Randall; Mokhtar, Bahaa; Parikh, Kapila.
Afiliação
  • Ashamalla H; Department of Radiation Oncology, New York Methodist Hospital, Weill Medical College of Cornell University, New York, NY, USA. hashamalla@aol.com
Int J Radiat Oncol Biol Phys ; 68(2): 388-95, 2007 Jun 01.
Article em En | MEDLINE | ID: mdl-17324530
ABSTRACT

PURPOSE:

To study anatomic biologic contouring (ABC), using a previously described distinct halo, to unify volume contouring methods in treatment planning for head and neck cancers. METHODS AND MATERIALS Twenty-five patients with head and neck cancer at various sites were planned for radiation therapy using positron emission tomography/computed tomography (PET/CT). The ABC halo was used in all PET/CT scans to contour the gross tumor volume (GTV) edge. The CT-based GTV (GTV-CT) and PET/CT-based GTV (GTV-ABC) were contoured by two independent radiation oncologists.

RESULTS:

The ABC halo was observed in all patients studied. The halo had a standard unit value of 2.19 +/- 0.28. The mean halo thickness was 2.02 +/- 0.21 mm. Significant volume modification (>or=25%) was seen in 17 of 25 patients (68%) after implementation of GTV-ABC. Concordance among observers was increased with the use of the halo as a guide for GTV determination 6 patients (24%) had a PET/CT (p < 0.001). Interobserver variability decreased from a mean GTV difference of 20.3 cm3 in CT-based planning to 7.2 cm3 in PET/CT-based planning (p < 0.001).

CONCLUSIONS:

Using the "anatomic biologic halo" to contour GTV in PET/CT improves consistency among observers. The distinctive appearance of the described halo and its presence in all of the studied tumors make it attractive for GTV contouring in head and neck tumors. Additional studies are needed to confirm the correlation of the halo with presence of malignant cells.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Tomografia por Emissão de Pósitrons / Neoplasias de Cabeça e Pescoço Tipo de estudo: Evaluation_studies / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Tomografia por Emissão de Pósitrons / Neoplasias de Cabeça e Pescoço Tipo de estudo: Evaluation_studies / Observational_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2007 Tipo de documento: Article