Your browser doesn't support javascript.
loading
T(1) and T(2) measurements of the fine structures of the in vivo and enucleated human eye.
Patz, Samuel; Bert, Robert J; Frederick, Eric; Freddo, Thomas F.
Afiliação
  • Patz S; Department Radiology, Brigham and Women's Hospital, Boston, Massachusetts 02115, USA. patz@bwh.harvard.edu
J Magn Reson Imaging ; 26(3): 510-8, 2007 Sep.
Article em En | MEDLINE | ID: mdl-17729342
ABSTRACT

PURPOSE:

To measure T(1) and T(2) of the fine structures of the in vivo eye. MATERIALS AND

METHODS:

Involuntary saccades make it difficult to obtain artifact-free images. Using a method recently reported (Bert et al, Acad Radiol 2006;12368-378), near artifact-free spin-echo images were obtained. Both an isolated enucleated eye and eight human subjects were studied at 1.5 T. Spin-echo variable TR/TE data was acquired for T(1)/T(2) determination. Average relaxation times were calculated two ways. First, an arithmetic average over different subjects was computed. Second, all data was normalized using the fitted amplitudes of each data set and pooled to obtain a single least squares fit.

RESULTS:

In vivo T(1)/T(2) (msec) are arithmetic average T(1), T(2), normalized data T(1), T(2). Anterior chamber 6233 +/- 979, 468 +/- 149, 5053 +/- 1052, 450 +/- 49. Ciliary body 1916 +/- 184, 80 +/- 7, 2038 +/- 114, 76 +/- 3. Chorioretina 1717 +/- 500, 72 +/- 25, 1511 +/- 230, 78 +/- 3. Extraocular muscle 1581 +/- 646, 41 +/- 7, 1470 +/- 231, 41 +/- 1. Iris 3334 +/- 989, 163 +/- 63, 3376 +/- 338, 153 +/- 10. Lens cortex 1712 +/- 466, 93 +/- 36, 1413 +/- 177, 100 +/- 5. Lens nucleus 1133 +/- 40, 26 +/- 3, 1138 +/- 47, 25 +/- 0.4. Optic nerve 1906 +/- 301, 68 +/- 16, 1805 +/- 244, 71 +/- 2. Posterior chamber 7915 +/- 4897, 241 +/- 14, 3323 +/- 2154, 251 +/- 38. Vitreous humor 5768 +/- 1190, 756 +/- 804, 4855 +/- 1846, 390 +/- 8.

CONCLUSION:

In vivo T(1) and T(2) for many of the fine structures of the human eye have been measured.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Espectroscopia de Ressonância de Spin Eletrônica / Olho Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Espectroscopia de Ressonância de Spin Eletrônica / Olho Tipo de estudo: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2007 Tipo de documento: Article