Reconstruction of rapidly acquired Germanium-68 transmission scans for cardiac PET attenuation correction.
Hsu, Bai-Ling; Case, James A; Moser, Kevin W; Bateman, Timothy M; Cullom, S James.
Afiliação
  • Hsu BL; Cardiovascular Imaging Technologies, LLC, Kansas City, MO 64111, USA. bhsu@cvit.com
J Nucl Cardiol ; 14(5): 706-14, 2007.
Article em En | MEDLINE | ID: mdl-17826324
ABSTRACT

BACKGROUND:

Transmission (TX) scan time by use of radionuclide sources for cardiac positron emission tomography prolong imaging and increase the likelihood of patient motion artifacts. A reconstruction algorithm combining ordered-subsets expectation maximization with a Bayesian prior was developed and applied to rapid Germanium-68 (Ge-68) TX scans. METHODS AND

RESULTS:

A cardiac phantom with Fluorine-18 (Fl-18) was used to determine a minimal count threshold for Ge-68 TX scanning. Images were acquired over a count range from 2.5 x 10(6) to 8 x 10(7) and for a high-count scan of 1.6 x 10(9) counts to study reconstruction parameters and to determine the minimum TX count threshold. The method was compared against clinical 4-minute TX scans in ten Rubidium-82 (Rb-82) rest/stress myocardial perfusion studies (body mass index, 30 +/- 4 kg/m(2)). The minimal count threshold was 20 x 10(6), and the mean scan time for the Rb-82 studies was 70.5 +/- 3.4 seconds. More than 90% of the segmental scores computed from images acquired via rapid TX scans differed by less than 5% from those obtained with 4-minute TX scans. The mean differences in perfusion scores between the rapid and 4-minute TX scans were 0.46% (95% confidence interval, -1.84% to 0.93%) at rest and 0.39% (95% confidence interval, -1.84% to 1.07%) at stress, demonstrating equivalency of the rapid and 4-minute scans.

CONCLUSIONS:

Ordered-subsets expectation maximization with a Bayesian prior accurately and efficiently reconstructs rapidly acquired Ge-68 TX scans for Rb-82 myocardial perfusion positron emission tomography studies.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Algoritmos / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Artefatos / Tomografia por Emissão de Pósitrons / Germânio Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radioisótopos / Algoritmos / Interpretação de Imagem Assistida por Computador / Aumento da Imagem / Artefatos / Tomografia por Emissão de Pósitrons / Germânio Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2007 Tipo de documento: Article