Your browser doesn't support javascript.
loading
Restenosis of the CYPHER-Select, TAXUS-Express, and Polyzene-F nanocoated cobalt-chromium stents in the minipig coronary artery model.
Radeleff, Boris; Thierjung, Heidi; Stampfl, Ulrike; Stampfl, Sibylle; Lopez-Benitez, Ruben; Sommer, Christof; Berger, Irina; Richter, Goetz M.
Afiliação
  • Radeleff B; Department of Radiology, University Heidelberg, INF 110, 69120, Heidelberg, Germany. Boris.radeleff@med.uni-heidelberg.de
Cardiovasc Intervent Radiol ; 31(5): 971-80, 2008.
Article em En | MEDLINE | ID: mdl-18095019
ABSTRACT

PURPOSE:

To date no direct experimental comparison between the CYPHER-Select and TAXUS-Express stents is available. Therefore, we investigated late in-stent stenosis, thrombogenicity, and inflammation, comparing the CYPHER-Select, TAXUS-Express, and custom-made cobalt chromium Polyzene-F nanocoated stents (CCPS) in the minipig coronary artery model.

METHODS:

The three stent types were implanted in the right coronary artery of 30 minipigs. The primary endpoint was in-stent stenosis assessed by quantitative angiography and microscopy. Secondary endpoints were inflammation and thrombogenicity evaluated by scores for inflammation and immunoreactivity (C-reactive protein and transforming growth factor beta). Follow-up was at 4 and 12 weeks.

RESULTS:

Stent placement was successful in all animals; no thrombus deposition occurred. Quantitative angiography did not depict statistically significant differences between the three stent types after 4 and 12 weeks. Quantitative microscopy at 4 weeks showed a statistically significant thicker neointima (p = 0.0431) for the CYPHER (105.034 +/- 62.52 microm) versus the TAXUS (74.864 +/- 66.03 microm) and versus the CCPS (63.542 +/- 39.57 microm). At 12 weeks there were no statistically significant differences. Inflammation scores at 4 weeks were significantly lower for the CCPS and CYPHER compared with the TAXUS stent (p = 0.0431). After 12 weeks statistical significance was only found for the CYPHER versus the TAXUS stent (p = 0.0431). The semiquantitative immunoreactivity scores for C-reactive protein and transforming growth factor beta showed no statistically significant differences between the three stent types after 4 and 12 weeks.

CONCLUSIONS:

The CCPS provided effective control of late in-stent stenosis and thrombogenicity in this porcine model compared with the two drug-eluting stents. Its low inflammation score underscores its noninflammatory potential and might explain its equivalence to the two DES.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Falha de Prótese / Doença das Coronárias / Reestenose Coronária / Stents Farmacológicos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2008 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Polímeros / Falha de Prótese / Doença das Coronárias / Reestenose Coronária / Stents Farmacológicos Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2008 Tipo de documento: Article