Your browser doesn't support javascript.
loading
Low-dose, time-resolved, contrast-enhanced 3D MR angiography in cardiac and vascular diseases: correlation to high spatial resolution 3D contrast-enhanced MRA.
Krishnam, M S; Tomasian, A; Lohan, D G; Tran, L; Finn, J P; Ruehm, S G.
Afiliação
  • Krishnam MS; Department of Radiological Sciences, University of California at Los Angeles, Los Angeles, CA 90095-7206, USA. mkrishnam@mednet.ucla.edu
Clin Radiol ; 63(7): 744-55, 2008 Jul.
Article em En | MEDLINE | ID: mdl-18555032
ABSTRACT

AIM:

To evaluate the effectiveness of low-dose, contrast-enhanced, time-resolved, three-dimensional (3D) magnetic resonance (MR) angiography (TR-MRA) in the assessment of various cardiac and vascular diseases, and to compare the results with high-resolution contrast-enhanced MRA (CE-MRA). MATERIALS AND

METHODS:

Thirty consecutive patients underwent contrast-enhanced 3D TR-MRA and high spatial resolution 3D CE-MRA for evaluation of cardiac and thoracic vascular diseases at 1.5 T, and neurovascular, abdominal and peripheral vascular diseases at 3T. Gadolinium-based contrast medium was administered at a constant dose of 5 ml for TR-MRA, and 20 ml (lower extremity 30 ml) for CE-MRA. Two readers evaluated image quality using a four-point scale (from 0=excellent to 3=non-diagnostic), artefacts and findings on both datasets. Interobserver variability was tested with kappa coefficient.

RESULTS:

The overall image quality for TR-MRA was in the diagnostic range (median 0, range 0-1; k=0.74). Readers demonstrated important additional dynamic information on TR-MRA in 28 of 30 patients (k=0.84). Confident evaluation of organ perfusion (n=23), arteriovenous malformation/fistula flow patterns (n=7), exclusion of intra-cardiac shunts (n=6), and assessment of stent and conduit patency (n=5) were performed by both readers using TR-MRA. Readers demonstrated fine vascular details with higher confidence in 10 patients on CE-MRA. Using CE-MRA, Reader 1 and 2 depicted anatomical details in 6 and 5 patients, respectively, only on CE-MRA.

CONCLUSION:

Low-dose TR-MRA yields rapid and important functional and anatomical information in patients with cardiac and vascular diseases. Due to limited spatial resolution, TR-MRA is inferior to CE-MRA in demonstrating fine vascular details.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Angiografia por Ressonância Magnética / Meios de Contraste / Gadolínio DTPA / Imageamento Tridimensional / Cardiopatias Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2008 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares / Angiografia por Ressonância Magnética / Meios de Contraste / Gadolínio DTPA / Imageamento Tridimensional / Cardiopatias Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2008 Tipo de documento: Article