Your browser doesn't support javascript.
loading
Automated cardiac motion compensation in PET/CT for accurate reconstruction of PET myocardial perfusion images.
Khurshid, Khawar; McGough, Robert J; Berger, Kevin.
Afiliação
  • Khurshid K; Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI 48824, USA.
Phys Med Biol ; 53(20): 5705-18, 2008 Oct 21.
Article em En | MEDLINE | ID: mdl-18812649
ABSTRACT
Error-free reconstruction of PET data with a registered CT attenuation map is essential for accurate quantification and interpretation of cardiac perfusion. Misalignment of the CT and PET data can produce an erroneous attenuation map that projects lung attenuation parameters onto the heart wall, thereby underestimating the attenuation and creating artifactual areas of hypoperfusion that can be misinterpreted as myocardial ischemia or infarction. The major causes of misregistration between CT and PET images are the respiratory motion, cardiac motion and gross physical motion of the patient. The misalignment artifact problem is overcome with automated cardiac registration software that minimizes the alignment error between the two modalities. Results show that the automated registration process works equally well for any respiratory phase in which the CT scan is acquired. Further evaluation of this procedure on 50 patients demonstrates that the automated registration software consistently aligns the two modalities, eliminating artifactual hypoperfusion in reconstructed PET images due to PET/CT misregistration. With this registration software, only one CT scan is required for PET/CT imaging, which reduces the radiation dose required for CT-based attenuation correction and improves the clinical workflow for PET/CT.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reconhecimento Automatizado de Padrão / Aumento da Imagem / Tomografia Computadorizada por Raios X / Técnica de Subtração / Tomografia por Emissão de Pósitrons / Coração Tipo de estudo: Diagnostic_studies / Evaluation_studies Idioma: En Ano de publicação: 2008 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reconhecimento Automatizado de Padrão / Aumento da Imagem / Tomografia Computadorizada por Raios X / Técnica de Subtração / Tomografia por Emissão de Pósitrons / Coração Tipo de estudo: Diagnostic_studies / Evaluation_studies Idioma: En Ano de publicação: 2008 Tipo de documento: Article