Your browser doesn't support javascript.
loading
Cranial computed tomography angiography with automated bone subtraction: a feasibility study.
Lell, Michael M; Ruehm, Stefan G; Kramer, Manuel; Panknin, Christoph; Habibi, Reza; Klotz, Ernst; Villablanca, Pablo.
Afiliação
  • Lell MM; Department of Radiological Sciences, David Geffen School of Medicine at UCLA, Los Angeles, CA, USA. michael.lell@uk-erlangen.de
Invest Radiol ; 44(1): 38-43, 2009 Jan.
Article em En | MEDLINE | ID: mdl-18836384
ABSTRACT

OBJECTIVES:

Computed tomography angiography (CTA) is becoming an increasingly accepted noninvasive alternative to catheter angiography. To display continuous vessel contours without superimposed bone in a similar manner, postprocessing of the CTA data is necessary. Threshold-based techniques often fail in regions of close vessel-bone contact, which frequently requires user interaction to optimize the results. This may be laborious and time consuming. The aim of this study was to assess the feasibility of a fully automated algorithm for bone subtraction in cranial CT angiography. MATERIALS AND

METHODS:

Forty-nine patients underwent cranial CT angiography on 64 slice CT systems. Two scans were performed, one before (mask) and one after (CTA) contrast agent administration. Images were processed with commercially available subtraction software. Two examiners rated the success of overall bone removal and image quality of different vessel segments (n = 34) with a 4-point scale (1 = poor; 4 = excellent); original CTA data served as the reference.

RESULTS:

Subtraction was performed successfully in all cases, overall subtraction quality was high (82% of cases were rated good or excellent). Only 50 of 1666 arterial segments (3%) were rated nondiagnostic. No relevant artificial stenoses of the internal carotid artery (ICA) or vertebral artery along their way through the skull base were detected when comparing CTA source images to bone subtraction computed tomography angiography (BSCTA) images.

CONCLUSIONS:

Automatic subtraction provides diagnostic image quality for 3D visualization of intracranial vessels, free from over projecting bone in a fully automatic way. Aneurysms can be evaluated from all angles, and ICA stenoses at the skull base were easily visualized.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Crânio / Algoritmos / Reconhecimento Automatizado de Padrão / Angiografia Cerebral / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Transtornos Cerebrovasculares Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Crânio / Algoritmos / Reconhecimento Automatizado de Padrão / Angiografia Cerebral / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Transtornos Cerebrovasculares Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2009 Tipo de documento: Article