Your browser doesn't support javascript.
loading
Arm raising at exposure-controlled multidetector trauma CT of thoracoabdominal region: higher image quality, lower radiation dose.
Brink, Monique; de Lange, Frank; Oostveen, Luuk J; Dekker, Helena M; Kool, Digna R; Deunk, Jaap; Edwards, Michael J R; van Kuijk, Cornelis; Kamman, Richard L; Blickman, Johan G.
Afiliação
  • Brink M; Department of Diagnostic Imaging, Radboud University Nijmegen Medical Centre, Nijmegen, the Netherlands. M.Brink@rad.umcn.nl
Radiology ; 249(2): 661-70, 2008 Nov.
Article em En | MEDLINE | ID: mdl-18936319
ABSTRACT

PURPOSE:

To evaluate the effect of arm position on image quality and effective radiation dose in an automatic exposure-controlled (AEC) multidetector thoracoabdominal computed tomography (CT) protocol in trauma patients. MATERIALS AND

METHODS:

This retrospective study of the data of 177 trauma patients (117 male; median age, 39 years) was approved by the institutional ethics board, with informed patient consent waived. Patients underwent scanning by using an AEC 16-detector thoracoabdominal CT protocol in which both arms were raised above the shoulder region (standard-position group, 132 patients), one arm was raised and the other was down (one-arm group, 27 patients), or both arms were down (two-arm group, 18 patients). Objective and subjective image quality was assessed. Individual effective radiation dose was calculated from the effective tube current-time product per exposed section. For this purpose, section location-dependent conversion factors were derived by using a CT dosimetry calculator. The effect of arm position on effective dose was quantified by using linear regression analysis with correction for patient volume and attenuation.

RESULTS:

Compared with the image quality in the standard-position group, the image quality in the one- and two-arm groups was decreased but within acceptable diagnostic limits. The median corrected effective dose in the standard-position group was 18.6 mSv; the dose in the one-arm group was 18% (95% confidence interval 11%, 25%) higher than this, and that in the two-arm group was 45% (95% confidence interval 34%, 57%) higher.

CONCLUSION:

Omitting arm raising results in lower but acceptable image quality and a substantially higher effective radiation dose. Hence, effort should be made to position the arms above the shoulder when scanning trauma patients. Clinical trial registration no. NCT00228111.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braço / Postura / Ferimentos não Penetrantes / Tomografia Computadorizada por Raios X Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2008 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Braço / Postura / Ferimentos não Penetrantes / Tomografia Computadorizada por Raios X Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2008 Tipo de documento: Article