Your browser doesn't support javascript.
loading
Quantitative analysis of tympanic membrane perforation: a simple and reliable method.
Ibekwe, T S; Adeosun, A A; Nwaorgu, O G.
Afiliação
  • Ibekwe TS; Department of Surgery, Division of ENT, Irrua Specialist Teaching Hospital, College of Medicine, Ambrose Alli University, Ekpoma, Nigeria.
J Laryngol Otol ; 123(1): e2, 2009 Jan.
Article em En | MEDLINE | ID: mdl-18940030
ABSTRACT

BACKGROUND:

Accurate assessment of the features of tympanic membrane perforation, especially size, site, duration and aetiology, is important, as it enables optimum management. AIM AND

OBJECTIVES:

To describe a simple, cheap and effective method of quantitatively analysing tympanic membrane perforations. MATERIALS AND

METHODS:

The system described comprises a video-otoscope (capable of generating still and video images of the tympanic membrane), adapted via a universal serial bus box to a computer screen, with images analysed using the Image J geometrical analysis software package. The reproducibility of results and their correlation with conventional otoscopic methods of estimation were tested statistically with the paired t-test and correlational tests, using the Statistical Package for the Social Sciences version 11 software.

RESULTS:

The following equation was generated P/T x 100 per cent = percentage perforation, where P is the area (in pixels2) of the tympanic membrane perforation and T is the total area (in pixels2) for the entire tympanic membrane (including the perforation). Illustrations are shown. Comparison of blinded data on tympanic membrane perforation area obtained independently from assessments by two trained otologists, of comparative years of experience, using the video-otoscopy system described, showed similar findings, with strong correlations devoid of inter-observer error (p = 0.000, r = 1). Comparison with conventional otoscopic assessment also indicated significant correlation, comparing results for two trained otologists, but some inter-observer variation was present (p = 0.000, r = 0.896). Correlation between the two methods for each of the otologists was also highly significant (p = 0.000).

CONCLUSION:

A computer-adapted video-otoscope, with images analysed by Image J software, represents a cheap, reliable, technology-driven, clinical method of quantitative analysis of tympanic membrane perforations and injuries.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico por Computador / Perfuração da Membrana Timpânica / Otoscopia Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico por Computador / Perfuração da Membrana Timpânica / Otoscopia Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2009 Tipo de documento: Article