Your browser doesn't support javascript.
loading
[Ablation of right ventricular outflow tract tachycardias under guidance of noncontact mapping system]. / Sag ventrikül çikis yolu tasikardilerinin temassiz haritalama sistemi kilavuzlugunda ablasyonu.
Diker, Erdem; Canbay, Alper; Celebi, Ozlem Ozcan; Sahin, Deniz; Uçar, Ozgül; Aydogdu, Sinan.
Afiliação
  • Diker E; Ankara Numune Egitim ve Arastirma Hastanese Kardiyoloji Klinigi, Ankara, Turkey. erdem.diker@isbank.net.tr
Turk Kardiyol Dern Ars ; 36(5): 294-301, 2008 Jul.
Article em Tr | MEDLINE | ID: mdl-18984980
ABSTRACT

OBJECTIVES:

We evaluated the efficiency of noncontact mapping, a new mapping technique, for the catheter ablation of right ventricular outflow tract tachycardias. STUDY

DESIGN:

The study included 13 symptomatic patients (4 males, 9 females; mean age 39+/-15 years) with a structurally normal heart, who had sustained ventricular tachycardia (VT) or nonsustained VT with ventricular premature beats (VPB), all arising from the right ventricular outflow tract. For noncontact mapping-guided (EnSite) ablation, first right ventricular geometry was reconstructed. Then, voltage maps of the right ventricle were obtained during sinus rhythm and tachycardia (or ectopic) beats. Index arrhythmia was induced in the form of sustained VT in three patients, and nonsustained VT or VPB in 10 patients. Radiofrequency was applied to endocardial foci of tachycardia beats using a standard, 4-mm ablation catheter.

RESULTS:

The endocardial breakthrough sites of the beats were the posterior septum in seven patients, anterior septum in four patients, and posterior free wall in two patients. A mean of 25 (range 7 to 45) radiofrequency current deliveries were applied to the target sites. The mean procedure time was 190 minutes. Index arrhythmia was eliminated in 10 patients after the procedure. No serious complications occurred during or after the procedure.

CONCLUSION:

Our experience with radiofrequency ablation of right ventricular outflow tract tachycardias under noncontact mapping guidance shows that this procedure can be performed efficiently and safely in our country.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Taquicardia Ventricular / Ablação por Cateter / Mapeamento Potencial de Superfície Corporal Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: Tr Ano de publicação: 2008 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Taquicardia Ventricular / Ablação por Cateter / Mapeamento Potencial de Superfície Corporal Tipo de estudo: Guideline / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male Idioma: Tr Ano de publicação: 2008 Tipo de documento: Article