Skeletonization with an ultrasonic scalpel is as safe as a non-skeletonized dissection in preserving the endothelial function of the human gastroepiploic artery.
Interact Cardiovasc Thorac Surg
; 8(2): 216-20, 2009 Feb.
Article
em En
| MEDLINE
| ID: mdl-19000990
The right gastroepiploic artery (GEA) is frequently used as another in situ artery, other than the internal thoracic artery (ITA) in coronary artery bypass grafting (CABG). Skeletonizing the graft with an ultrasonic scalpel is now regarded as a useful technique; however, this technique may damage the endothelial function during harvesting the graft resulting in postoperative graft stenosis or occlusion. In the present study, GEA segments from nine patients were excised in both a skeletonized and non-skeletonized manner with an ultrasonic scalpel, and then were transported to the laboratory. The vessels were trimmed as rings, and were allotted to the group of skeletonized or non-skeletonized, accordingly. The force development in response to 1 mumol/l norepinephrine did not differ between the skeletonized and non-skeletonized groups. Endothelium-dependent relaxation induced by either acetylcholine or bradykinin was not impaired in the skeletonized group in comparison to the non-skeletonized group. No significant difference was observed in endothelium-independent relaxation elicited by sodium nitroprusside. Therefore, the skeletonization of the GEA with an ultrasonic scalpel was thus found to be as safe as a non-skeletonized dissection in preserving the vascular contractile ability or endothelium-dependent and -independent relaxation of the graft.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Ultrassom
/
Endotélio Vascular
/
Ponte de Artéria Coronária
/
Coleta de Tecidos e Órgãos
/
Artéria Gastroepiploica
/
Dissecação
Limite:
Aged
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2009
Tipo de documento:
Article