ABSTRACT
The purpose of this study was to evaluate the correlation between real-time intra-operative ultrasound-based dosimetry (USD) and day 0 post-implant CT dosimetry (CTD) (131)Cs permanent prostate brachytherapy. Fifty-two consecutive patients who underwent prostate brachytherapy with (131)Cs were evaluated. Real time operating room planning was performed using VariSeed 7.1 software. Post-needle placement prostate volume was used for real-time planning. Targets for dosimetry were D(90) >110%, V(100) >90%, V(150) <50%, and V(200) <20%. The CT scan for post-operative dosimetry was obtained on day 0. The mean values for USD, CTD, and the linear correlation, respectively, were, for D(90) 114.0%, 105.61%, and 0.15; for V(100) 95.1%, 91.6%, and 0.22; for V(150) 51.5%, 46.4%, and 0.40; and for V(200) 15.8%, 17.9%, and 0.42. The differences between the mean values for USD and CTD for D(90) (p<0.01), V(100) (p<0.01), and V(150) (p<0.05) were statistically significant. For D(90), 30.8% of patients had a >15% difference between USD and CTD and 51.9% of patients had a >10% difference between these values. In contrast, the USD and CTD for V(100) were within 5% in 55.8% of patients and within 10% in 86.5% of patients. This study demonstrates a correlation between the mean intra-operative USD and post-implant day 0 CTD values only for V(200). Significant variation in D(90), V(150), and V(200) values existed for individual patients between USD and CTD. These results suggest that real-time intra-operative USD does not serve as a surrogate for post-operative CTD, and that post-operative CTD is still necessary.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radiometria / Braquiterapia / Radioisótopos de Césio / Ultrassonografia Tipo de estudo: Diagnostic_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2008 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Próstata / Radiometria / Braquiterapia / Radioisótopos de Césio / Ultrassonografia Tipo de estudo: Diagnostic_studies Limite: Aged / Humans / Male / Middle aged Idioma: En Ano de publicação: 2008 Tipo de documento: Article