Your browser doesn't support javascript.
loading
Reliability of treadmill testing in peripheral arterial disease: a meta-regression analysis.
Nicolaï, Saskia P A; Viechtbauer, Wolfgang; Kruidenier, Lotte M; Candel, Math J J M; Prins, Martin H; Teijink, Joep A W.
Afiliação
  • Nicolaï SP; Department of Surgery, Atrium Medical Center Parkstad, Heerlen, The Netherlands.
J Vasc Surg ; 50(2): 322-9, 2009 Aug.
Article em En | MEDLINE | ID: mdl-19631868
ABSTRACT

OBJECTIVE:

A meta-regression analysis was conducted to identify the most reliable treadmill protocol for the assessment of patients with peripheral arterial disease (PAD).

BACKGROUND:

Treadmill testing is the main assessment method to evaluate walking ability in patients with PAD in clinical studies. Reported treadmill protocols are continuous (C) and graded (G) protocols and outcome measurements are initial claudication distance (ICD) and absolute claudication distance (ACD). Variety in protocols might hamper the ability to compare results of different studies. Ideally, future studies should use a protocol with highest reliability.

METHODS:

We searched PubMed and EMBASE (until February 2008) and we hand searched the reference lists. Trials assessing reliability of treadmill testing were identified. Inclusion criteria were the use of a C- or G-protocol, repetition of this protocol, and a retrievable intraclass correlation coefficient (ICC). We identified eight studies in which 658 patients were included.

RESULTS:

For ICD, the estimated reliabilities of the C- and G-protocol (as assessed by the ICC) were 0.85 (95% confidence interval [CI] 0.82-0.88) and 0.83 (95% CI 0.80-0.85), respectively, without dependency of the reliability on velocity or grade. For ACD, the reliability was significantly better for the G-protocol (0.95, 95% CI 0.94-0.96) than for the C-protocol. Moreover, the reliability of the C-protocol was dependent on grade of the treadmill (0%, 10%, and 12%) with a mean ICC of 0.76 (95% CI 0.54-0.88), 0.89 (95% CI 0.86-0.91), and 0.91 (95% CI 0.88-0.92), respectively.

CONCLUSION:

Treadmill assessment has the highest reliability when using a G-protocol together with the ACD as the primary outcome measure.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares Periféricas / Teste de Esforço Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doenças Vasculares Periféricas / Teste de Esforço Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2009 Tipo de documento: Article