Your browser doesn't support javascript.
loading
Effect of input states of polarization on the measurement error of Mueller matrix in a system having small polarization-dependent loss or gain.
Dong, H; Gong, Y D; Paulose, Varghese; Shum, P; Olivo, Malini.
Afiliação
  • Dong H; Institute for Infocomm Research, 1 Fusionopolis Way, # 21-01 Connexis, Singapore 138632. hdong@i2r.a-star.edu.sg
Opt Express ; 17(15): 13017-30, 2009 Jul 20.
Article em En | MEDLINE | ID: mdl-19654706
For the measurement of Mueller matrix in an optical system with birefringence and small polarization-dependent loss or gain (PDL/G), we theoretically derive the statistical relationship between the Mueller matrix measurement error and three input states of polarization (SOP). Based on this theoretical relation and simulation results, it can be concluded that the three input SOPs, that are coplanar with an angle of 120 degrees between any two of them in Stokes space, can be considered as a substitute for the best input SOPs which can statistically lead to the minimum measurement error. This conclusion is valid when the PDL/G of the optical system under test is less than 0.35 dB.
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2009 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2009 Tipo de documento: Article