Your browser doesn't support javascript.
loading
Dual-gated cardiac PET-clinical feasibility study.
Teräs, Mika; Kokki, Tommi; Durand-Schaefer, Nicolas; Noponen, Tommi; Pietilä, Mikko; Kiss, Jan; Hoppela, Erika; Sipilä, Hannu T; Knuuti, Juhani.
Afiliação
  • Teräs M; Turku PET Centre, PO BOX 52, 20521, Turku, Finland. mika.teras@tyks.fi
Eur J Nucl Med Mol Imaging ; 37(3): 505-16, 2010 Mar.
Article em En | MEDLINE | ID: mdl-19789872
ABSTRACT

PURPOSE:

Both respiratory and cardiac motions reduce image quality in myocardial imaging. For accurate imaging of small structures such as vulnerable coronary plaques, simultaneous cardiac and respiratory gating is warranted. This study tests the feasibility of a recently developed robust method for cardiac-respiratory gating. List-mode data with triggers from respiratory and cardiac cycles are rearranged into dual-gated segments and reconstructed with standard algorithms of a commercial PET/CT scanner. Cardiac gates were defined as three fixed phases and one variable diastolic phase. Chest motion was measured with a respiratory gating device and post-processed to determine gates. Preservation of quantification in dual-gated images was tested with an IEC whole-body phantom.

METHODS:

Minipig and human studies were performed to evaluate the feasibility of the method. In minipig studies, a coronary catheter with radioactive tip was guided in coronary artery for in vivo and ex vivo acquisitions. Dual gating in humans with suspected cardiac disorders was performed using 18-F-FDG as a tracer.

RESULTS:

The method was found feasible for in vivo imaging and the radioactive catheter tip was better resolved in gated images. In human studies, the dual gating was found feasible and easy for clinical routine. Maximal movement of myocardial surface in cranio-caudal direction was over 20 mm. The shape of myocardium was clearly different between the gates and papillary muscles become more visible in diastolic images.

CONCLUSION:

The first clinical experiences using robust cardiac-respiratory dual gating are encouraging. Further testing in larger clinical populations using tracers designed especially for plaque imaging is warranted.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons / Técnicas de Imagem de Sincronização Cardíaca / Técnicas de Imagem de Sincronização Respiratória / Coração Limite: Animals / Humans Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons / Técnicas de Imagem de Sincronização Cardíaca / Técnicas de Imagem de Sincronização Respiratória / Coração Limite: Animals / Humans Idioma: En Ano de publicação: 2010 Tipo de documento: Article