ABSTRACT

BACKGROUND:

We have previously demonstrated that the use of a daily "Quality Rounds Checklist" (QRC) can increase compliance with evidence-based prophylactic measures and decrease complications in a busy trauma intensive care unit (ICU) over a 3-month period. This study was designed to determine the sustainability of QRC use over 1 year and examine the relationship between compliance and outcome improvement.

METHODS:

A prospective before-after design was used to examine the effectiveness of the QRC tool in documenting compliance with 16 prophylactic measures for ventilator-associated pneumonia (VAP), deep venous thrombosis, pulmonary embolism, catheter-related bloodstream infection, and other ICU complications. The QRC was implemented on a daily basis for a 1-year period by the ICU fellow on duty. Monthly compliance rates were assessed by a multidisciplinary team for development of strategies for real-time improvement. Compliance and outcomes were captured over 1 year of QRC use.

RESULTS:

QRC use was associated with a sustained improvement of VAP bundle and other compliance measures over a year of use. After multivariable analysis adjusting for age (> 55), injury mechanism, Glasgow Coma Scale score (≤ 8), and Injury Severity Score (> 20), the rate of VAP was significantly lower after QRC use, with an adjusted mean difference of -6.65 (per 1,000 device days; 95% confidence interval, -9.27 to -4.04; p = 0.008). During the year of QRC use, 3% of patients developed a VAP if all four daily bundle measures were met for the duration of ICU stay versus 14% in those with partial compliance (p = 0.04). The overall VAP rate with full compliance was 5.29 versus 9.23 (per 1,000 device days) with partial compliance. Compared with the previous year, a 24% decrease in the number of pneumonias was recorded for the year of QRC use, representing an estimated cost savings of approximately $400,000.

CONCLUSION:

The use of a QRC facilitates sustainable improvement in compliance rates for clinically significant prophylactic measures in a busy Level I trauma ICU. The daily use of the QRC, requiring just a few minutes per patient to complete, equates to cost-effective improvement in patient outcomes.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ferimentos e Lesões / Medicina Baseada em Evidências / Indicadores de Qualidade em Assistência à Saúde / Pneumonia Associada à Ventilação Mecânica / Lista de Checagem / Unidades de Terapia Intensiva Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ferimentos e Lesões / Medicina Baseada em Evidências / Indicadores de Qualidade em Assistência à Saúde / Pneumonia Associada à Ventilação Mecânica / Lista de Checagem / Unidades de Terapia Intensiva Tipo de estudo: Observational_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2010 Tipo de documento: Article