Processed electroencephalogram during donation after cardiac death.
Anesth Analg
; 110(5): 1428-32, 2010 May 01.
Article
em En
| MEDLINE
| ID: mdl-20237048
We present a case series of increased bispectral index values during donation after cardiac death (DCD). During the DCD process, a patient was monitored with processed electroencephalogram (EEG), which showed considerable changes traditionally associated with lighter planes of anesthesia immediately after withdrawal of care. Subsequently, to validate the findings of this case, processed EEG was recorded during 2 other cases in which care was withdrawn without the use of hypnotic or anesthetic drugs. We found that changes in processed EEG immediately after withdrawal of care were not only reproducible, but can happen in the absence of changes in major electromyographic or electrocardiographic artifact. It is well documented that processed EEG is prone to artifacts. However, in the setting of DCD, these changes in processed EEG deserve some consideration. If these changes are not due to artifact, dosing of hypnotic or anesthetic drugs might be warranted. Use of these drugs during DCD based primarily on processed EEG values has never been addressed.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Doadores de Tecidos
/
Transplante de Órgãos
/
Morte
/
Eletroencefalografia
Tipo de estudo:
Prognostic_studies
Limite:
Aged
/
Humans
/
Male
/
Middle aged
Idioma:
En
Ano de publicação:
2010
Tipo de documento:
Article