ABSTRACT

OBJECTIVE:

Pseudoaneurysms are characterized by extravascular circulation and therefore may lead to an activation of the coagulation cascade. We investigated d-dimer levels in patients with and without postcatheterization femoral pseudoaneurysms and hypothesized that d-dimer levels correlate with the presence of pseudoaneurysms at the vascular access site.

METHODS:

Patients with clinical suspected groin pseudoaneurysms after transluminal procedures were eligible. We compared prospectively-collected laboratory values of quantitative d-dimer testing in patients with and without pseudoaneurysms as assessed by color-coded duplex sonography. Furthermore, we measured the peak systolic velocity at the arterial fistula of each pseudoaneurysm.

RESULTS:

In 48 (40%) of 120 consecutive patients, a pseudoaneurysm was found. The level of d-dimer values was significantly higher in patients with postcatheterization femoral pseudoaneurysms compared with controls (1.9 microg/mL [interquartile range (IQR), 1.34-2.78 microg/mL] vs 0.8 microg/mL [IQR, 0.53-1.14 microg/mL]; P < .001). Values of d-dimer below 0.67 microg/mL have been calculated with a sensitivity of 94% (87%-100%), a specificity of 38% (27%-50%), a positive predictive value of 50% (40%-60%), a negative predictive value of 90% (82%-99%), and a likelihood ratio of 1.52 (1.25-1.85) with regard to the presence of pseudoaneurysms. We also found a significant correlation of the peak systolic velocity at the arterial fistula and increasing d-dimer levels (r = 0.98, P < .0001).

CONCLUSION:

We found a significantly higher level of d-dimer values in patients with femoral pseudoaneurysms at the vascular access site. Therefore, d-dimer levels could be a potential serological marker in the diagnosis of pseudoaneurysms. A confirmation is warranted in a larger patient sample.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Produtos de Degradação da Fibrina e do Fibrinogênio / Fístula Vascular / Doenças Vasculares Periféricas / Falso Aneurisma / Angioplastia com Balão / Artéria Femoral Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Produtos de Degradação da Fibrina e do Fibrinogênio / Fístula Vascular / Doenças Vasculares Periféricas / Falso Aneurisma / Angioplastia com Balão / Artéria Femoral Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article