Your browser doesn't support javascript.
loading
Recovery of distal coronary flow reserve in LAD and LCx after Y-Graft intervention assessed by transthoracic echocardiography.
Auriti, Antonio; Loiaconi, Vincenzo; Pristipino, Christian; Leonardi Cattolica, Francesco Saverio; Cini, Roberto; Guido, Vincenzo; Cianfrocca, Cinzia; Greco, Salvatore; Agostini, Filomena; Staibano, Mario; Santini, Massimo.
Afiliação
  • Auriti A; Department of Cardiovascular Disease, Echocardiography Lab, S,Filippo Neri Hospital, Rome, Italy. a.auriti@sanfilipponeri.roma.it
Cardiovasc Ultrasound ; 8: 34, 2010 Aug 17.
Article em En | MEDLINE | ID: mdl-20716357
ABSTRACT

BACKGROUND:

Y- graft (Y-G) is a graft formed by the Left Internal Mammary Artery (LIMA) connected to the Left Anterior Descending Artery (LAD) and by a free Right Internal Mammary Artery (RIMA) connected to LIMA and to a Marginal artery of Left Circumflex Artery (LCx). Aim of the work was to study the flow of this graft during a six months follow-up to assess whether the graft was able to meet the request of all the left coronary circulation, and to assess whether it could be done by evaluation of coronary flow reserve (CFR).

METHODS:

In 13 consecutive patients submitted to Y-G (13 men), CFR was measured in distal LAD and in distal LCx from 1 week after , every two months, up to six months after operation (a total of 8 tests for each patient) by means of transthoracic echocardiography (TTE) and Adenosine infusion (140 mcg/kg/min for 3-6 min). A Sequoia 256, Acuson-Siemens, was used. Contrast was used when necessary (Levovist 300 mg/ml solution at a rate of 0,5-1 ml/min). Max coronary flow diastolic velocity post-/pre-test > or =2 was considered normal CFR.

RESULTS:

Coronary arteriography revealed patency of both branches of Y-G after six months. Accuracy of TTE was 100% for LAD and 85% for LCx. Feasibility was 100% for LAD and 85% for LCx. CFR improved from baseline in LAD (2.21 +/- 0.5 to 2.6 +/- 0.5, p = 0.03) and in LCx (1.7 +/- 1 to 2.12 +/- 1, p = 0.05). CFR was under normal at baseline in 30% of patients vs 8% after six months in LAD (p = 0.027), and in 69% of patients vs 30% after six months in LCx (p = 0.066).

CONCLUSION:

CFR in Y-G is sometimes reduced in both left territories postoperatively but it improves at six months follow-up. A follow-up can be done non-invasively by TTE and CFR evaluation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Ponte de Artéria Coronária / Circulação Coronária / Vasos Coronários / Recuperação de Função Fisiológica / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ecocardiografia / Ponte de Artéria Coronária / Circulação Coronária / Vasos Coronários / Recuperação de Função Fisiológica / Infarto do Miocárdio Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Humans / Male / Middle aged Idioma: En Ano de publicação: 2010 Tipo de documento: Article