Your browser doesn't support javascript.
loading
Screening of platelets for bacterial contamination at the Welsh Blood Service.
Pearce, S; Rowe, G P; Field, S P.
Afiliação
  • Pearce S; Welsh Blood Service, Laboratory Services, Pontyclun, UK. stephen.pearce@wales.nhs.uk
Transfus Med ; 21(1): 25-32, 2011 Feb.
Article em En | MEDLINE | ID: mdl-20854460
BACKGROUND AND OBJECTIVE: This report details the results of the implementation of a bacterial screening system at the Welsh Blood Service and provides an estimate of the levels of bacterial contamination at the time of sampling. MATERIALS AND METHODS: Apheresis (Caridian BCT) and buffy coat-derived pooled platelet components were sampled on day 1 for bacterial contamination and the sample was monitored throughout the lifespan of the platelet component. Unused platelet components were re-tested to determine the effectiveness of the screening. Results from the BacT/ALERT are uploaded to the in-house Blood Establishment Computer System (BECS) every 12 min. Positive alerts are automatically sent to staff, facilitating a timely intervention. RESULTS: Between February 2003 and March 2010 the screening system tested 54 828 platelets and detected 257 (1 in 213) initial positives of which 35 (1 in 1567, 0·06%) were confirmed [95% confidence interval (CI), 0·04-0·08%]. Additionally, screening of 6438 unused platelet components detected another 6 (1 in 1073, 0·09%) confirmed positives not detected during initial testing (95% CI, 0·02-0·16%). Analysis of the data suggests that on day 1 the number of bacteria in such platelet component packs was between 5 and 62 cfus total. Day 1 culture has a sensitivity of 40%. CONCLUSIONS: The bacterial screening system has removed a significant number, but not all bacterially contaminated platelet components from the supply. The sample volume is an important factor in sensitivity due to the low number of bacteria in a platelet component pack on day 1. An effective notification and recall system is a critical part of the bacterial screening system.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plaquetas / Armazenamento de Sangue Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plaquetas / Armazenamento de Sangue Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans País/Região como assunto: Europa Idioma: En Ano de publicação: 2011 Tipo de documento: Article