Your browser doesn't support javascript.
loading
Human papillomavirus 16 (HPV 16) and HPV 18 antibody responses measured by pseudovirus neutralization and competitive Luminex assays in a two- versus three-dose HPV vaccine trial.
Krajden, Mel; Cook, Darrel; Yu, Amanda; Chow, Ron; Mei, Wendy; McNeil, Shelly; Money, Deborah; Dionne, Marc; Karunakaran, Karuna P; Palefsky, Joel M; Dobson, Simon; Ogilvie, Gina; Petric, Martin.
Afiliação
  • Krajden M; BC Centre for Disease Control, 655 West 12th Avenue, Vancouver BC V5Z 4R4, Canada. mel.krajden@bccdc.ca
Clin Vaccine Immunol ; 18(3): 418-23, 2011 Mar.
Article em En | MEDLINE | ID: mdl-21248158
ABSTRACT
Human papillomavirus 16 (HPV 16) and HPV 18 antibody responses in a 2- versus 3-dose HPV vaccine (Gardasil) trial were measured by a pseudovirus neutralizing antibody (PsV NAb) assay and by the Merck competitive Luminex immunoassay (cLIA). Eight hundred twenty-four female subjects assigned to three dosing regimens (group 1, 9 to 13 years old; 2 doses, months 0 and 6 [n = 259]; group 2, 9 to 13 years old; 3 doses, months 0, 2, and 6 [n = 260]; group 3, 16 to 26 years old; 3 doses, months 0, 2, and 6 [n = 305]) had postvaccine responses assessed 1 month after the last dose. Of 791 subjects with baseline and 7-month sera, 15 (1.9%) and 9 (1.1%) were baseline seropositive for HPV 16 and HPV 18, respectively. All baseline-seronegative vaccinees seroconverted to both HPV 16 and HPV 18. Mean anti-HPV 16 levels were similar for groups 1 and 2 (for PsV NAb, P = 0.675; for cLIA, P = 0.874), and levels for both groups 1 and 2 were approximately 2-fold higher than that for group 3 (for PsV NAb and cLIA, P < 0.001). Mean anti-HPV 18 levels were approximately 1.4-fold lower in group 1 than in group 2 (for PsV, NAb P = 0.013; for cLIA, P = 0.001), and levels for both groups 1 and 2 were approximately 2.0- to 2.5-fold higher than that for group 3 (for PsV NAb and cLIA, P < 0.001). Pearson correlation coefficients for the assays were 0.672 for HPV 16 and 0.905 for HPV 18. Most of the discordant results were observed at lower cLIA signals. These results suggest that the PsV NAb assay could be a suitable alternative to cLIA for the measurement of postvaccine antibody responses.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Laboratório Clínico / Papillomavirus Humano 16 / Papillomavirus Humano 18 / Vacinas contra Papillomavirus / Anticorpos Neutralizantes / Anticorpos Antivirais Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adolescent / Adult / Child / Female / Humans Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Técnicas de Laboratório Clínico / Papillomavirus Humano 16 / Papillomavirus Humano 18 / Vacinas contra Papillomavirus / Anticorpos Neutralizantes / Anticorpos Antivirais Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adolescent / Adult / Child / Female / Humans Idioma: En Ano de publicação: 2011 Tipo de documento: Article