[Comparison between Lenstar LS 900 non-contact biometry and OcuScan RXP contact biometry for task delegation]. / Comparaison de la biométrie sans contact cornéen par LENSTAR LS 900 et de la biométrie contact par OCUSCAN RXP dans le cadre de la délégation de tâches.
J Fr Ophtalmol
; 34(3): 175-80, 2011 Mar.
Article
em Fr
| MEDLINE
| ID: mdl-21257228
INTRODUCTION: Non-contact biometers have many advantages including the delegation of tasks to orthoptists. This study analyses the reliability of measurements comparing contact and non-contacts techniques. PATIENTS AND METHODS: Comparative measurements were taken on 86 eyes of 45 patients (mean age: 74 years; 44.4 % males) in preoperative phacoemulsification by three orthoptists with experience in this task. Each patient had non-contact measurements (Lenstar LS 900, Haag-Streit) and contact measurements (corneal biometry and ultrasound pachymetry with OcuScan RXP, Alcon) and a keratometry refractometer (TONOREF II, Nidek). The axial length data, pachymetry, power of the intraocular lens (SRK/T formula), anterior chamber depth, and the average keratometry were analyzed by paired comparisons. RESULTS: The non-contact biometer was ineffective in 5.8 % of cases (Parkinson's disease, two cases; dense posterior subcapsular cataracts, three cases). The non-contact pachymetry was statistically significantly higher (546.4 µm vs. 538.6 µm; p<0.001). The axial length was significantly longer for the non-contact measurement (23.21 mm vs. 23.05 mm; p<0.0001). In 25.9 % of patients, this difference was greater than or equal to 0.3mm and affected the power of the implant chosen. The anterior chamber depth measured on non-contact biometry was statistically greater (3.33 mm vs. 3.03 mm; p<0.0001). However, there was no significant difference regarding the average keratometry (43.82 D vs. 43.78 D; p=0327). CONCLUSION: Besides the infectious benefit for patients, absence of cleaning and decontamination of biometric probes, non-contact measurements using Lenstar are an example of a safe activity that can be delegated to assistants. This technique has been used to optimize the refractive outcome of 25.9 % of our patients undergoing refractive cataract surgery.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Ortóptica
/
Refratometria
/
Catarata
/
Biometria
/
Córnea
/
Designação de Pessoal
/
Técnicas de Diagnóstico Oftalmológico
/
Pessoal Técnico de Saúde
/
Interferometria
/
Cristalino
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
/
Risk_factors_studies
Limite:
Adult
/
Aged
/
Aged80
/
Female
/
Humans
/
Male
/
Middle aged
Idioma:
Fr
Ano de publicação:
2011
Tipo de documento:
Article