Your browser doesn't support javascript.
loading
Prone imaging allows efficient radiopharmaceutical usage by obviating the necessity of a rest study in Tc-99m-methoxyisobutylisonitrile myocardial perfusion scintigraphy.
Ceylan Gunay, Emel; Erdogan, Alihan; Yalcin, Hulya; Ozcan Kara, Pelin.
Afiliação
  • Ceylan Gunay E; Department of Nuclear Medicine, Faculty of Medicine, Mersin University, Mersin, Turkey. ecgunay@yahoo.com
Nucl Med Commun ; 32(4): 284-8, 2011 Apr.
Article em En | MEDLINE | ID: mdl-21304414
ABSTRACT

OBJECTIVE:

In myocardial perfusion single-photon emission computed tomography studies, diaphragmatic attenuation of the inferior wall is a common artifact, which can be minimized by prone imaging. The aim of this retrospective study was to validate the impact of stress-prone imaging on the necessity of a rest perfusion study with a final goal of effective radiopharmaceutical usage.

METHODS:

The findings of 98 patients who had been examined by a combined supine and prone imaging were retrospectively evaluated. Prone acquisition was performed only when reduced perfusion was observed in the inferior wall on the stress supine images. The reconstructed images were evaluated both visually and quantitatively. Rest myocardial single-photon emission computed tomography study was omitted in patients with complete normalization of uptake in the prone images. Results obtained were also compared with the clinical data and follow-up.

RESULTS:

Prone imaging obviated the necessity of a rest perfusion study in 76 of 98 patients (77.5%). Among normally reported patients (n=89), 76 (85.4%) were saved from a rest study due to the prone study results. Prone study provided improved results in quantitative analysis as well. The difference between the mean summed stress scores of supine and prone studies was statistically significant in normally reported patients (P=0.013). However, no significant difference was observed in scores of ischemic patients (P=0.341).

CONCLUSION:

Adding prone imaging to a post-stress Tc-99m-methoxyisobutylisonitrile myocardial perfusion study not only minimizes the inferior wall attenuation, but also reduces the need for a rest test, particularly in low-risk or intermediate-risk patients. Thus, prone imaging seems to be both safe and effective.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Tecnécio / Decúbito Ventral / Tecnécio Tc 99m Sestamibi / Compostos Radiofarmacêuticos / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Tecnécio / Decúbito Ventral / Tecnécio Tc 99m Sestamibi / Compostos Radiofarmacêuticos / Imagem de Perfusão do Miocárdio Tipo de estudo: Diagnostic_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article