An analysis of inflation times during balloon-assisted aneurysm coil embolization and ischemic complications.
Spiotta, Alejandro M; Bhalla, Tarun; Hussain, Muhammad S; Sivapatham, Thinesh; Batra, Ayush; Hui, Ferdinand; Rasmussen, Peter A; Moskowitz, Shaye I.
Afiliação
  • Spiotta AM; Department of Neurological Surgery, Cerebrovascular Center, Cleveland Clinic, 9500 Euclid Avenue, S40, Cleveland, OH 44195, USA. spiotta@ccf.org
Stroke ; 42(4): 1051-5, 2011 Apr.
Article em En | MEDLINE | ID: mdl-21311066
ABSTRACT
BACKGROUND AND

PURPOSE:

The introduction of balloon remodeling has revolutionized the approach to coiling of wide-neck aneurysms. We studied the effects of balloon inflation during coil embolization on ischemic complications.

METHODS:

A retrospective review was undertaken of the most recent 147 patients undergoing balloon remodeling for unruptured intracranial aneurysm coil embolization at a single institution (81 balloon, 66 unassisted). All underwent postprocedural MRI.

RESULTS:

Among patients in the "balloon" group, the mean total inflation time was 18 minutes (range, 1-43), a mean number of inflations of 4 (range, 1-9), a mean maximum single inflation time of 7 minutes (range, 1-19), a mean reperfusion time of 2.2 minutes between inflations, and an average procedure time of 2 hours and 10 minutes. Asymptomatic diffusion-weighted imaging abnormalities were detected on postprocedural MRI in 21.5% of patients and symptomatic lesions were identified in 3.8%. Both silent and symptomatic ischemic rates were similar in the internal control group. Patients with ischemic findings were older and more likely have diabetes; no differences were found with respect to total balloon inflation time, number of inflations, maximum inflation time, or reperfusion times.

CONCLUSIONS:

We found no significant relationship between balloon inflation practices and ischemic events. Older and diabetic patients were more likely to have ischemic events develop.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Aneurisma Intracraniano / Isquemia Encefálica / Implante de Prótese Vascular / Oclusão com Balão Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Complicações Pós-Operatórias / Aneurisma Intracraniano / Isquemia Encefálica / Implante de Prótese Vascular / Oclusão com Balão Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article