Your browser doesn't support javascript.
loading
Iodine-124 as a label for pharmacological PET imaging.
Belov, Vasily V; Bonab, Ali A; Fischman, Alan J; Heartlein, Michael; Calias, Pericles; Papisov, Mikhail I.
Afiliação
  • Belov VV; Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts, USA.
Mol Pharm ; 8(3): 736-47, 2011 Jun 06.
Article em En | MEDLINE | ID: mdl-21361362
ABSTRACT
With the growing number of biotechnology products and drug delivery systems entering preclinical and clinical studies, pharmacological imaging studies with PET play an increasingly significant role. Such studies often require investigation of slow and complex pharmacokinetics (PK). This suggests labeling of the drug candidate with radionuclides that have long physical half-lives. Among the currently available PET positron emitters, ¹²4I has the longest physical half-life (4.2 days). This, combined with the well-investigated behavior of iodine in vivo, makes ¹²4I very attractive for pharmacological studies. However, the high energy of the positrons emitted by ¹²4I and the presence of single photons in the ¹²4I emission can potentially introduce limitations in the quantitative analysis of the images. The objective of this research was to determine whether the use of ¹²4I as a PET label provides data quality suitable for PK studies. The study was carried out using MicroPET P4 scanner (Siemens/Concorde Microsystems). Spatial resolution, count-rate performance, sensitivity and scatter fraction were measured using a line source and a cylindrical phantom. Model animal studies in rats and cynomolgus monkeys were carried out using human recombinant proteins. The proteins were labeled with ¹²4I, up to 185 MBq/mg. The transaxial and axial spatial resolutions in the center of the camera were satisfactory and higher for OSEM3D/MAP than FORE-2DFBP (FWHM 2.52 vs 3.31 mm, and 3.10 vs 3.69 mm). Linearity of the true coincidence count-rate was observed up to 44 MBq. Animal studies demonstrated excellent delineation and resolution of even very small organs. At optimal doses, 2-10 MBq per animal for rodents and 4-10 MBq per kg of body weight for larger animals, the quality of numerical data was appropriate for PK analysis in all experimental timeframes from minutes (dynamic studies) to 10 days. Overall, the data suggest that ¹²4I is an excellent label for quantitative pharmacological PET imaging studies.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons / Radioisótopos do Iodo Limite: Animals / Humans Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Tomografia por Emissão de Pósitrons / Radioisótopos do Iodo Limite: Animals / Humans Idioma: En Ano de publicação: 2011 Tipo de documento: Article