Impact of attenuation correction and gated acquisition in SPECT myocardial perfusion imaging: results of the multicentre SPAG (SPECT Attenuation Correction vs Gated) study.
Genovesi, Dario; Giorgetti, Assuero; Gimelli, Alessia; Kusch, Annette; D'Aragona Tagliavia, Irene; Casagranda, Mirta; Cannizzaro, Giorgio; Giubbini, Raffaele; Bertagna, Francesco; Fagioli, Giorgio; Rossi, Massimiliano; Romeo, Annadina; Bertolaccini, Pietro; Bonini, Rita; Marzullo, Paolo.
Afiliação
  • Genovesi D; Nuclear Medicine, Fondazione CNR-Regione Toscana G. Monasterio, Via G. Moruzzi 1, 56124, Pisa, Italy. dario.genovesi@ifc.cnr.it
Eur J Nucl Med Mol Imaging ; 38(10): 1890-8, 2011 Oct.
Article em En | MEDLINE | ID: mdl-21656244
PURPOSE: In clinical myocardial single photon emission computed tomography (SPECT), attenuation artefacts may cause a loss of specificity in the identification of diseased vessels that can be corrected by means of gated SPECT (GSPECT) acquisition or CT attenuation correction (AC). The purpose of this multicentre study was to assess the impact of GSPECT and AC on the diagnostic performance of myocardial scintigraphy, according to patient's sex, body mass index (BMI) and site of coronary artery disease (CAD). METHODS: We studied a group of 104 patients who underwent coronary angiography within 1 month before or after the SPECT study. Patients with a BMI>27 were considered "overweight". Attenuation-corrected and standard GSPECT early images were randomly interpreted by three readers blinded to the clinical data. RESULTS: In the whole group, GSPECT and AC showed a diagnostic accuracy of 86.5% (sensitivity 82%, specificity 93%) and 77% (sensitivity 75.4%, specificity 81.4%), respectively (p<0.05). In women, when anterior ischaemia was matched with CAD, AC failed to show any increase in specificity (AC 63.6% vs GSPECT 63.6%) with evident loss of sensitivity (AC 72.7% vs GSPECT 90.9%). AC significantly improved SPECT specificity in the identification of right CAD in overweight men (AC 100% vs GSPECT 66.7%, p<0.05). CONCLUSION: AC improved specificity in the evaluation of right CAD in overweight men. In the other evaluable subgroups specificity was not significantly affected while sensitivity was frequently reduced.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Artefatos / Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca / Imagem de Perfusão do Miocárdio Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Artefatos / Tomografia Computadorizada por Emissão de Fóton Único de Sincronização Cardíaca / Imagem de Perfusão do Miocárdio Tipo de estudo: Clinical_trials / Prognostic_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2011 Tipo de documento: Article