Your browser doesn't support javascript.
loading
Low-permeability Gore Excluder device versus the original in abdominal aortic aneurysm size regression.
Krajcer, Zvonimir; Rajan, Lawrence; Thota, Venkata; Dougherty, Kathryn G; Strickman, Neil E; Mortazavi, Ali; Cheong, Benjamin Y C.
Afiliação
  • Krajcer Z; Division of Cardiology, Texas Heart Institute at St. Luke's Episcopal Hospital, TXx 77030, USA. ZvonkoMD@aol.com
Tex Heart Inst J ; 38(4): 381-5, 2011.
Article em En | MEDLINE | ID: mdl-21841865
ABSTRACT
We sought to compare the efficacy of a low-permeability version of the Gore Excluder™ device with that of the original device. We used volumetric analysis and maximum transverse diameter measurements to examine abdominal aortic aneurysm size regression after endovascular aneurysm repair.From November 2002 through April 2007, 101 patients (82% men; mean age, 71.5 ± 8.9 yr) underwent endovascular aneurysm repair with the Excluder stent-graft 34 with the original device, and 67 with the low-permeability device. Only patients without endoleak and with preprocedural and 1- and 2-year follow-up computed tomographic scans were included. Eight patients with type II endoleak and 2 with type I endoleak were excluded. Maximum abdominal aortic aneurysm diameter and volume were measured before endovascular aneurysm repair and annually thereafter. Postprocessing, multiplanar computed tomography, and 3-dimensional reconstructions were compared with baseline measurements. Diameter and volume changes that were greater than 5 mm or that exceeded 10% were considered significant.At 12 months, the mean maximum transverse diameter had decreased by -0.16 ± 12.1 mm in recipients of the original device and by -4.8 ± 5.9 mm in recipients of the low-permeability device (P = NS). In addition, mean reduction in volume had changed by -17 ± 16 mL in original-device recipients and by -36.1 ± 37.9 mL in low-permeability device recipients (P < 0.01).One-year follow-up revealed that the low-permeability stent-graft resulted in a greater decrease in abdominal aortic aneurysm volume than did the original stent-graft.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Observational_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2011 Tipo de documento: Article