Accuracy of neonatal transcutaneous bilirubin measurement in the outpatient setting.
Clin Pediatr (Phila)
; 50(12): 1144-9, 2011 Dec.
Article
em En
| MEDLINE
| ID: mdl-22013149
OBJECTIVE. To evaluate the effectiveness of transcutaneous bilirubin (TcB) measurement in predicting risk for neonatal hyperbilirubinemia in outpatients. DESIGN. Subjects were infants ≤8 days old seen in an outpatient clinic. Infants discharged with high-risk (HR) or high-intermediate risk (HIR) total serum bilirubin (TSB) values and jaundiced infants were recruited. TSB and TcB (BiliChek) levels were plotted on an hour-specific nomogram to determine risk for hyperbilirubinemia. RESULTS. A total of 79 infants provided 87 sets of TcB and TsB values. Mean bias and standard deviation between TcB and TsB was 1.5 ± 2.1 mg/dL for outpatients, compared with 2.7 ± 1.3 mg/dL for inpatients. The sensitivity and specificity of HR or HIR TcB for predicting an HR or HIR TSB were 87% and 58%, respectively. Of 9 infants readmitted for phototherapy, 1 had a low-risk TcB and high-risk TSB. CONCLUSIONS. TcB screening in the outpatient environment may not be safe and efficient.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Bilirrubina
/
Triagem Neonatal
/
Hiperbilirrubinemia Neonatal
/
Assistência Ambulatorial
Tipo de estudo:
Diagnostic_studies
/
Etiology_studies
/
Observational_studies
/
Prognostic_studies
Limite:
Humans
/
Newborn
Idioma:
En
Ano de publicação:
2011
Tipo de documento:
Article