Your browser doesn't support javascript.
loading
Relative magnitude of vascular reactivity in the major arterioles of the retina.
Sehi, Mitra; Tsui, Edmund; Cheng, Richard; Wan, Jennifer; Wong, Tien; Dorner, Stephanie; Fisher, Joseph; Hudson, Christopher.
Afiliação
  • Sehi M; Bascom Palmer Eye Institute, Department of Ophthalmology, Miller School of Medicine, University of Miami, Palm Beach Gardens, FL, USA.
Microvasc Res ; 83(2): 200-4, 2012 Mar.
Article em En | MEDLINE | ID: mdl-22100560
ABSTRACT
The relative magnitude of vascular reactivity to inhaled gas stimuli in the major retinal arterioles has not been systematically investigated. The purpose of this study was to compare the magnitude of retinal vascular reactivity in response to inhaled gas provocation at equivalent measurement sites in the superior-, and inferior-, temporal retinal arterioles (STA, ITA). One randomly selected eye of each of 17 healthy volunteers (age 24.4 ± 4.7) was prospectively enrolled. Volunteers were connected to a sequential gas delivery circuit and a computer-controlled gas blender (RespirAct™, Thornhill Research Inc., Canada) and underwent an isocapnic hyperoxic challenge i.e. P(ET)O(2) of 500 mm Hg with P(ET)CO(2) maintained at 38 mm Hg during baseline and hyperoxia. Four retinal hemodynamic measurements were acquired using bi-directional laser Doppler velocimetry and simultaneous vessel densitometry (Canon Laser Blood Flowmeter, CLBF-100, Japan) at equivalent positions on the STA and ITA. Statistical analysis was performed using linear mixed-effect models. During the hyperoxic phase, the vessel diameter (STA p=0.004; ITA p=0.003), blood velocity (STA p<0.001; ITA p<0.001) and flow (STA p<0.001; ITA p<0.001) decreased in both the STA and the ITA relative to baseline. The diameter, velocity and flow were equivalent between STA and ITA at baseline and during hyperoxia; and their magnitude of change remained comparable with hyperoxia (p>0.05). The magnitude of retinal arteriolar vascular reactivity in response to isocapnic hyperoxic inhaled gas challenge was not significantly different between the STA and ITA. However, the correlation analysis did not reveal a significant relationship between the percentage changes in diameter, velocity and flow of the STA and ITA and did not demonstrate equal responses from the STA and ITA to gas provocation.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasos Retinianos / Hiperóxia / Hemodinâmica / Hipercapnia Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Vasos Retinianos / Hiperóxia / Hemodinâmica / Hipercapnia Tipo de estudo: Clinical_trials / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male País/Região como assunto: America do norte Idioma: En Ano de publicação: 2012 Tipo de documento: Article