Your browser doesn't support javascript.
loading
Usefulness of dynamic contrast-enhanced MRI in differentiating between septic arthritis and transient synovitis in the hip joint.
Kim, Eun Young; Kwack, Kyu-Sung; Cho, Jae Ho; Lee, Doo-Hyung; Yoon, Seung-Hyun.
Afiliação
  • Kim EY; Department of Radiology, Ajou University School of Medicine, San 5, Woncheon-dong, Yeongtong-gu, Suwon 443-721, Republic of Korea.
AJR Am J Roentgenol ; 198(2): 428-33, 2012 Feb.
Article em En | MEDLINE | ID: mdl-22268189
ABSTRACT

OBJECTIVE:

The purpose of this study was to show the usefulness of dynamic contrast-enhanced MRI (DCE-MRI) and to determine the optimal time window in MRI for differentiating between septic arthritis and transient synovitis in painful hip joints. MATERIALS AND

METHODS:

Eighteen patients who underwent DCE-MRI were enrolled, and the final diagnoses were septic arthritis (n = 7) and transient synovitis (n = 11). The enhancement patterns of DCE-MRI were dichotomized according to the shape of the time-signal intensity curves. The time at the maximal difference in the signal intensity between two time-signal intensity curves of both femoral heads was recorded. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated. Receiver operating characteristic curves were calculated.

RESULTS:

Six of seven patients with septic arthritis in the hip joint had decreased enhancement during the early phase of DCE-MRI. The enhancement difference between the two patient groups was statistically significant (p = 0.0498). The time at the maximal difference in the signal intensity between two time-signal intensity curves of both femoral heads was approximately 3.5 minutes. The area under the receiver operating characteristic curve for predicting septic arthritis was 0.792.

CONCLUSION:

DCE-MRI is useful in differentiating between septic hip arthritis and transient synovitis. If static contrast-enhanced coronal MRI is used, the optimal time for the acquisition of contrast-enhanced coronal MRI is approximately 3.5 minutes.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sinovite / Imageamento por Ressonância Magnética / Artrite Infecciosa / Articulação do Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Infant / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sinovite / Imageamento por Ressonância Magnética / Artrite Infecciosa / Articulação do Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adolescent / Adult / Aged / Child / Child, preschool / Female / Humans / Infant / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article