Your browser doesn't support javascript.
loading
Mid-term clinical and angiographic results of cerebral aneurisms treated with matrix2(®) coils.
Moritz, Jorge Luís Wollstein; Vendrell, Jean François; Hoa, Denis; Menjot, Nicolas; Costalat, Vincent; Brunel, Hervé; Bonafé, Alain.
Afiliação
  • Moritz JL; Division of Interventional Neuroradiology, Hôpital Gui de Chauliac, CHU de Montpellier, 80, avenue Augustin-Fliche, 34295 Montpellier, France. jorgelwm@yahoo.com.br
J Neuroradiol ; 39(5): 326-31, 2012 Dec.
Article em En | MEDLINE | ID: mdl-22269816
OBJECTIVE: To evaluate 1 year results of endovascular treatment (EVT) of intracranial aneurisms using Matrix second generation detachable coils (MSG(®)). PATIENTS AND METHODS: Between January and December 2006, 32 patients with 32 intracranial aneurisms were treated by coiling using MSG(®), with a minimum follow-up of 1 year. Data were acquired prospectively. Exclusion criteria were: permanent adjunctive device, less than 50% MSG(®) length, and additional bioactive or coated coils. All procedures were carried out in a single institution. Six months and 1 year follow-up were performed with magnetic resonance angiography and digital subtraction angiography, respectively. We assessed radiological and clinical results using the modified Raymond classification, a 3-level longitudinal grading scale (LGS), Glasgow outcome and Rankin scales. RESULTS: Thirteen (40.6%) male and 19 (59.4%) female underwent EVT using MSG(®) with a mean follow-up of 16.6 months. Ruptured aneurisms (75%) outnumbered unruptured. Immediate radiological results showed 15 complete occlusions (46.9%), 12 (37.5%) neck remnant, and five (15.6%) residual sac. In the mean time, six patients (18.7%) needed to be retreated due to insufficient initial packing or early recanalization. Using the LGS, a stable occlusion was observed in 40.7%, a progressive thrombosis in 25%, and 34.3% of the cases evolved unfavorably. Thirty-one patients had stable or improved clinical status, while one patient died from a thromboembolic event 1 month after retreatment (3.1% overall mortality). CONCLUSION: At 1 year follow-up, MSG(®) demonstrated similar angiographic results compared to Matrix first generation coils and didn't suggest advantage over platinum coils.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Cerebral / Aneurisma Intracraniano / Procedimentos Endovasculares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angiografia Cerebral / Aneurisma Intracraniano / Procedimentos Endovasculares Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article