Your browser doesn't support javascript.
loading
Signal-to-noise ratio increase in carotid atheroma MRI: a comparison of 1.5 and 3 T.
Young, V E; Patterson, A J; Tunnicliffe, E M; Sadat, U; Graves, M J; Tang, T Y; Priest, A N; Kirkpatrick, P J; Gillard, J H.
Afiliação
  • Young VE; Department of Radiology, Addenbrookes Hospital, Cambridge, UK. vy207@cam.ac.uk
Br J Radiol ; 85(1015): 937-44, 2012 Jul.
Article em En | MEDLINE | ID: mdl-22294703
ABSTRACT

OBJECTIVES:

This study reports quantitative comparisons of signal-to-noise ratio (SNR) at 1.5 and 3 T from images of carotid atheroma obtained using a multicontrast, cardiac-gated, blood-suppressed fast spin echo protocol.

METHODS:

18 subjects, with carotid atherosclerosis (>30% stenosis) confirmed on ultrasound, were imaged on both 1.5 and 3 T systems using phased-array coils with matched hardware specifications. T(1) weighted (T(1)W), T(2) weighted (T(2)W) and proton density-weighted (PDW) images were acquired with identical scan times. Multiple slices were prescribed to encompass both the carotid bifurcation and the plaque. Image quality was quantified using the SNR and contrast-to-noise ratio (CNR). A phantom experiment was also performed to validate the SNR method and confirm the size of the improvement in SNR. Comparisons of the SNR values from the vessel wall with muscle and plaque/lumen CNR measurements were performed at a patient level. To account for the multiple comparisons a Bonferroni correction was applied.

RESULTS:

One subject was excluded from the protocol owing to image quality and protocol failure. The mean improvement in SNR in plaque was 1.9, 2.1 and 2.1 in T(1)W, T(2)W and PDW images, respectively. All plaque SNR improvements were statistically significant at the p<0.05 level. The phantom experiment reported an improvement in SNR of 2.4 for PDW images.

CONCLUSIONS:

Significant gains in SNR can be obtained for carotid atheroma imaging at 3 T compared with 1.5 T. There was also a trend towards increased CNR. However, this was not significant after the application of the Bonferroni correction.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Intensificação de Imagem Radiográfica / Estenose das Carótidas / Placa Aterosclerótica / Razão Sinal-Ruído Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Intensificação de Imagem Radiográfica / Estenose das Carótidas / Placa Aterosclerótica / Razão Sinal-Ruído Tipo de estudo: Etiology_studies / Incidence_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2012 Tipo de documento: Article