Your browser doesn't support javascript.
loading
Initial experience of the i-gel supraglottic airway by the residents in pediatric patients.
Abukawa, Yukako; Hiroki, Koichi; Ozaki, Makoto.
Afiliação
  • Abukawa Y; Department of Anesthesia and Critical Care, Tokyo Women's Medical University, Tokyo, Japan. yukako1@rg8.so-net.ne.jp
J Anesth ; 26(3): 357-61, 2012 Jun.
Article em En | MEDLINE | ID: mdl-22310833
ABSTRACT

PURPOSE:

Insertion of a laryngeal mask airway (LMA) is occasionally difficult in children because of their anatomical features and variations. A new single-use supraglottic airway device, the i-gel airway, was recently introduced. The objective of this study was to show the initial experience of the i-gel airway device by the residents for pediatric patients.

METHODS:

With approval from the local ethics committee and parental informed consent, 70 children undergoing minor surgery in the supine position, ASA score I-II, were investigated. Exclusion included patients having thoracic, neurosurgical, spine, and otolaryngological procedures. Patients were divided into three groups group 1 was airway size 1.5 for patients weighing 5-12 kg, group 2 was size 2 for 10-25 kg, and group 3 was size 2.5 for those weighing 25-35 kg. The following seven characteristics were evaluated (1) ease of the i-gel and gastric tube insertion; (2) leak pressure; (3) tidal volume/body weight at leak pressure point; (4) fiberscope score; (5) insertion time; (6) hypoxia rate (laryngospasm); and (7) coughing and trace of bleeding.

RESULTS:

The overall insertion success rate and the success rate at first attempt were 99% and 94%, respectively. Gastric tube insertions were easy in all patients. The overall leak pressure was 23 ± 5 cmH(2)O. The tidal volume per body weight was 24 ± 10 ml/kg. A good view of the fiberscope was achieved in 79%. In group 1 (size 1.5), one failed insertion, two dislocations, and one dysphonia were observed. Hypoxia rate was 1%. There was no case with coughing and trace of bleeding.

CONCLUSION:

These results show that the i-gel airway is a safe and effective device for use by residents who do not have experience with insertion of a pediatric LMA. However, using size 1.5, special caution should be taken to protect the infant airway, similar to what has been previously reported for other airway devices.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas / Intubação Intratraqueal Tipo de estudo: Clinical_trials / Observational_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Máscaras Laríngeas / Intubação Intratraqueal Tipo de estudo: Clinical_trials / Observational_studies Limite: Adolescent / Child / Child, preschool / Female / Humans / Infant / Male Idioma: En Ano de publicação: 2012 Tipo de documento: Article