Your browser doesn't support javascript.
loading
Maintenance of surface antigens and the absence of an apoptotic marker are observed during storage of granulocyte concentrates collected by bag separation method.
Akaihata, M; Kikuta, A; Mochizuki, K; Nemoto, K; Ito, M; Sano, H; Kobayashi, S; Ohto, H; Hosoya, M.
Afiliação
  • Akaihata M; Department of Pediatrics, Fukushima Medical University School of Medicine, Fukushima, Japan. m-akai@fmu.ac.jp
Transfus Apher Sci ; 47(1): 43-7, 2012 Aug.
Article em En | MEDLINE | ID: mdl-22480955
Granulocytes were collected by the bag separation method and stored in whole blood for up to 72h. We evaluated the expressions of various surface antigens: CD62L, CD11b, CD18, CD64, CD16b, and CD95. Apoptosis was assessed both by flow cytometry and by light microscopy. Expression levels of all the surface antigens were shown to be maintained during storage for up to 72h. Approximately 80% of granulocytes were annexin V negative until 72h after collection. The storage of granulocyte concentrates collected by the bag separation method may maintain granulocyte surface antigens and lack an apoptotic marker.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Preservação de Sangue / Antígenos CD / Apoptose / Granulócitos Limite: Female / Humans / Male Idioma: En Ano de publicação: 2012 Tipo de documento: Article